Dimensions and Structure

Electric Two-Way Cast Steel Ball Valve
Electrically actuated two-way cast steel ball valve with stainless steel internal components and a separate actuator selection table. The source includes a reference actuator configuration; its ratings do not apply to every actuator option.
Materials and Service
| Parameter | Specification |
|---|---|
| Body | Cast steel |
| Ball, cover and stem | Stainless steel |
| Seal | NBR |
| Medium | Hot or cold water; 50% ethylene glycol |
| Medium temperature | 5-95 C |
| Nominal pressure | 1.6 MPa |
Actuator Selection Ranges for Soft-Seated Ball Valves
| Output torque (N m) | 0-90 degree time options (s) | Supply options | Compatible ball valve range |
|---|---|---|---|
| 25-33 | 5 / 10 / 15 | AC24V; AC110V; AC220V; AC380V; DC24V | Not specified unambiguously |
| 15-45 | 9 / 10 / 18 | AC24V; AC110V; AC220V; AC380V; DC24V | DN10-20 |
| 15-50 | 4 / 10 / 20 / 30 | AC24V; AC110V; AC220V; AC380V; DC24V | DN15-32 |
| 15-80 | 4 / 10 / 20 / 30 | AC24V; AC110V; AC220V; AC380V; DC24V | DN15-32 |
| 50-100 | 5 / 10 / 12 / 24 | AC24V; AC110V; AC220V; AC380V; DC24V | DN25-50 |
| 50-160 | 5 / 10 / 12 / 24 | AC24V; AC110V; AC220V; AC380V; DC24V | DN25-50 |
| 80-200 | 5 / 9 / 15 / 20 / 30 / 60 | AC24V; AC110V; AC220V; AC380V; DC24V | DN50-80 |
| 150-600 | Not specified unambiguously | AC24V; AC110V; AC220V; AC380V | DN50-125 |
| 800-1000 | 5 / 15 / 30 / 60 | AC24V; AC110V; AC220V; AC380V | DN65-150 |
| 2000 | 5 / 15 / 30 / 60 / 90 | AC24V; AC110V; AC220V; AC380V | DN65-250 |
Reference Actuator Configuration
| Parameter | Specification |
|---|---|
| Supply | 24 VDC +/-10% |
| Motor power | 25 W |
| Rated current in source | 2.2 A |
| 0-90 degree opening/closing time | 15 seconds |
| Output torque | 150 N m |
| Input signal | 4-20 mA DC |
| Weight | 4.7 kg |
| Protection | IP67 |
| Installation orientation | Any angle within 360 degrees |
| Electrical entries | Two M18 x 1.5 waterproof entries; one power and one signal |
| Ambient temperature | -25 to 60 C |
| Adjustable rotation range | 0-360 degrees |
| Insulation resistance | 100 megohms at250 VDC |
| Dielectric test | 500 VAC for1 minute |
| Basic error | Within +/-1% |
| Hysteresis | Less than1% |
| Adjustable deadband | 0.5-5% |
| Optional functions | Heater/dehumidifier; handwheel; torque protection; passive contact switch |
Actuator compatibility ranges are selection guidance, not valve dimensions. Use the selected actuator's confirmed ratings; the reference actuator table describes one configuration only. The source does not provide numeric valve face-to-face dimensions. Ambiguous timing and size entries are not inferred. The original source drawing is retained for structure reference: its CF8 marking conflicts with the WCB marking on the source photograph and the cast steel body description. The exact material grade and applicability of the drawing must be confirmed before selection. No material grade is specified here.