Dimensions and Structure

Stainless Steel Flanged Solenoid Valve
Stainless steel flanged solenoid valve for water and compatible fluid service, with AC or DC coil options and normally closed or normally open configurations. The dimensions and materials below refer to the selected configuration shown.
Dimensions – Selected Flanged Configuration
| DN | L (mm) | H (mm) | Flange holes N-d (mm) |
|---|---|---|---|
| 15 | 112 | 143 | 4-14 |
| 20 | 114 | 145 | 4-14 |
| 25 | 123 | 184 | 4-14 |
| 32 | 150 | 200 | 4-18 |
| 40 | 170 | 210 | 4-18 |
| 50 | 192 | 225 | 4-18 |
Materials and Service
| Parameter | Specification |
|---|---|
| Body | Stainless steel |
| Cover and disc | Brass |
| Stem | Stainless steel |
| Seal | NBR |
| Medium | Hot or cold water; 50% ethylene glycol |
| Nominal pressure | 1600 kPa |
| Working pressure listed in coil/valve data | 0-10 bar |
| Operating variants | Normally closed or normally open; select configuration |
| Medium temperature | Requires configuration confirmation |
Electrical Options
| Parameter | Specification |
|---|---|
| AC supply options | 220 V; 380 V; 110 V; 24 V |
| DC supply options | 24 V; 12 V |
| DN10-25 AC coil consumption | 26 VA |
| DN10-25 DC coil consumption | 18 W |
| DN32-50 AC coil consumption | 26 VA |
| DN32-50 DC coil consumption | 30 W |
| Iron-shell coil protection | IP54 |
Dimensions and materials apply only to the illustrated configuration, not to every valve in the family. Confirm the required coil supply, operating state, medium temperature and flange standard before ordering. The source gives inconsistent temperature ranges, so no temperature rating is asserted here. Unfilled sizes are omitted. The original drawing is a structural reference; its letter A must not be substituted for the table's L dimension.