DODOMACH PNEUMATIC

PNEUMATIC

Air Compressor Pressure Switch with Thermal Overload Protection

Pressure switch and thermal overload relay combination for air compressors and water pumps, with adjustable pressure limits, manual shut-off and four-port connection options.

Categories ,

Dimensions and Structure

Air Compressor Pressure Switch with Thermal Overload Protection dimensions

Air Compressor Pressure Switch with Thermal Overload Protection

Pressure-operated motor control for air compressors and water pumps, combined with a thermal overload relay. The switch starts and stops the motor at preset pressure limits. A manual rotary knob provides shut-off, while the selected unloader helps the compressor restart without load.

Pressure Selection

Adjustment range (bar) Differential range (bar) Factory cut-in / cut-out (bar)
1–6 0.7–2 2 / 3
3–11 1.5–3.5 6 / 8
6–16 2–7 9 / 12
5–25 3–8 16 / 20
12–35 3–8 25 / 30

Technical Specifications

Item Specification
Medium Water, air
Contact arrangement Multi-pole single-throw, normally closed
Fluid temperature −40 to +82 °C
Enclosure protection IP54
Cable size 10–14 AWG
Contact material Silver alloy, fixed and moving contacts
Thermal relay restart Allow 30 minutes for cooling
Motor cycle interval More than 5 minutes

Electrical Rating Options

Supply Catalog rating options
Single phase 120 V AC / 10 A; 230 V AC / 10 A
Three phase 120 V AC / 10 A; 230 V AC / 10 A
Three phase 400 V AC / 7.5 A or 11 A
Three phase 500 V AC / 6 A or 9 A
Three phase 690 V AC / 4.5 A or 6.5 A

Ordering Field B: Female Pressure Ports

Code Connection
1 G1/4 + 3 × G1/4
2 R1/4 + 3 × R1/4
3 1/4 NPT + 3 × 1/4 NPT
4 G3/8 + 3 × G1/4
5 R3/8 + 3 × R1/4
6 3/8 NPT + 3 × 1/4 NPT
7 G1/2 + 3 × G1/4
8 R1/2 + 3 × R1/4
9 1/2 NPT + 3 × 1/4 NPT

Ordering Field C: Unloader

Code Option
1 No unloader
2 Vertical M12, brass
3 Vertical Ø6 tube push-in, brass
4 Vertical oil-resistant M12, brass
5 Vertical oil-resistant Ø6 tube push-in, brass
6 Vertical oil-resistant M12, zinc alloy
7 Horizontal oil-resistant M12, zinc alloy

Other Ordering Fields

Field Code Selection
A 1 Four-port body
D 1 No unloading function
D 2 Tube outside diameter 6.0–6.1 mm
D 3 Tube outside diameter 6.4–6.5 mm
E 1 Adjustable current 2.5–4 A
E 2 Adjustable current 4–6.3 A
E 3 Adjustable current 6.3–10 A
E 4 Adjustable current 10–16 A
E 5 Adjustable current 16–20 A

Drawing Dimensions

Drawing feature Dimension (mm)
Top-view overall length 110
Top-view overall width 82
Top-view inner width 71
Height to top of manual knob 103
Housing reference height 92
Lower connection region height 50
Connection spacing shown 58.5
Offset shown 30

Select the pressure range and cut-in/cut-out settings, then specify ordering fields A–E for body, ports, unloader, tube connection and current adjustment. The selected thermal relay must suit the motor current and the switch electrical rating. Ratings are configuration-dependent; the listed current ranges do not mean every supply/rating combination is available. Dimensions are in millimetres and refer to the illustrated configuration.