Dimensions and Structure

Submersible Liquid Level Transmitter
Hydrostatic liquid level transmitter with an immersed pressure probe and vented cable. It converts liquid head into a selected current, voltage or RS485 signal for tanks, water supply systems, hydrological monitoring and compatible industrial liquids. Standard cable and remote display versions are available.
Level Measurement Specifications
| Item | Value |
|---|---|
| Measurement | Hydrostatic liquid level; gauge pressure reference |
| Range selection | Zero-based spans with full scale from 0.5 to 200 mH2O |
| Accuracy | ±0.5% FS at 25 °C; linearity, repeatability and hysteresis combined |
| Overload | 1.5 times rated pressure |
| Stability | <0.5% FS/year |
| Working temperature | −20 to +85 °C |
| Storage temperature | −40 to +100 °C |
| Medium | Liquids compatible with 304/316L stainless steel, PE, PVC and selected FKM or NBR seals |
| Probe protection | IP68; confirm selected immersion depth and cable assembly |
| Electrical connection | Direct cable outlet with vented cable |
Standard Version Output and Supply
| Code | Output | Wiring | Supply |
|---|---|---|---|
| A4 | 4–20 mA | Two-wire | 8–36 VDC |
| V05 | 0.5–4.5 V | Three-wire | 4.75–5.25 VDC |
| V0 | 0–5 V | Three-wire | 8–36 VDC |
| V10 | 0–10 V | Three-wire | 12–36 VDC |
| RS | RS485 | Four-wire | 10–30 VDC |
Display Version Output and Supply
| Output | Wiring | Supply |
|---|---|---|
| 4–20 mA | Two-wire | 10–30 VDC |
| 0–10 V | Three-wire | 14–36 VDC; confirm selected revision |
| RS485 | Four-wire | 10–36 VDC |
Selection Fields
| Field | Catalog selection |
|---|---|
| Level unit | M: metres; CM: centimetres |
| Accuracy grade | 0.5: ±0.5% FS |
| Electrical connection | M: direct cable outlet |
| Display | N: without display; display enclosure available subject to selected configuration |
| Mounting | T: submersible; M20: M20×1.5 installation |
| Cable | Select length to suit installation depth; catalog examples 1.0: 1 m, 2.0: 2 m |
Illustrated Dimensions
| Component | Dimension (mm) |
|---|---|
| Probe outside diameter | 28 |
| Probe assembly length | 160.4 |
| Display enclosure width | 86±2 |
| Display enclosure height | 133 |
Catalog reference: LFT3000. The photograph shows the remote display configuration. Tables distinguish the standard and display versions; do not interchange their supply ratings. The 0–10 V display version is listed here at 14–36 VDC, within the overlapping limits of the source editions; confirm the delivered revision. Match the selected level range, liquid density and cable length to the application. Keep the display enclosure and cable termination dry; the probe immersion rating does not establish a display-head immersion rating. RS485 protocol and intelligent Modbus configuration must be confirmed for the selected unit. Drawings retain the original supplier dimensions in millimetres. No hazardous-area certification or international-brand interchangeability is claimed.