Dimensions and Structure

Submersible Level and Temperature Transmitter
Submersible transmitter combining hydrostatic liquid-level measurement with a Pt100 temperature sensor. The integrated probe monitors both liquid head and temperature in compatible tanks, water-treatment systems and industrial liquids, using a selected current, voltage or RS485 configuration.
Measurement Specifications
| Item | Value |
|---|---|
| Measured variables | Liquid level and temperature |
| Level measurement | Hydrostatic pressure; piezoresistive sensor |
| Temperature sensor | Pt100 |
| Level range selection | Zero-based spans with full scale from 1 to 200 mH2O |
| Temperature measurement range | −20 to +100 °C |
| Pressure/level accuracy | ±0.5% FS |
| Temperature accuracy | ±2% FS |
| Accuracy basis | At 25 °C; includes linearity, repeatability and hysteresis |
| Overload | 1.5 times rated pressure |
| Stability | <0.5% FS/year |
| Working temperature | −20 to +85 °C |
| Storage temperature | −40 to +100 °C |
| Pressure reference | Gauge (G) |
| Medium | Liquids compatible with 304/316L stainless steel, PE, PVC and selected FKM or NBR seals |
| Protection | IP68; confirm immersion depth and cable assembly |
Output and Supply Selection
| Code | Signal option | Supply |
|---|---|---|
| A4 | 4–20 mA | 10–30 VDC |
| V05 | 0.5–4.5 V | 4.75–5.25 VDC |
| RS | RS485 | 10–30 VDC |
Other Selection Fields
| Field | Catalog option |
|---|---|
| Level unit | M: metres; CM: centimetres |
| Accuracy codes | 0.5: pressure/level; 2: temperature |
| Electrical connection | M: direct cable outlet in the selected catalog |
| Mounting | T: submersible; M20: M20×1.5 installation |
| Cable length | Select for installation depth; catalog examples 1.0: 1 m, 2.0: 2 m, 3.0: 3 m |
Dimensions of Selected Catalog Version
| Dimension | Value (mm) |
|---|---|
| Probe assembly length | 160.4 |
| Cylindrical body length | 110.4 |
| Outside diameter | 28 |
Catalog reference: LFT3200. Select the level and temperature ranges, output, accuracy, cable length and installation arrangement. Confirm both measurement-channel assignments and the wiring diagram for the selected version before connection. Intelligent RS485 versions support Modbus according to the manufacturer; confirm the delivered protocol settings and register map. Match level calibration to liquid density and installation depth. Keep the cable termination dry. Dimensions shown are from the selected supplier catalog; another manufacturer specification lists a different probe length, so confirm the dimensional revision and cable-entry configuration when ordering. The photo is the manufacturer’s LFT3200 series image. No hazardous-area certification or international-brand interchangeability is claimed.