Dimensions and Structure

Temperature and Humidity Transmitter
Combined temperature and relative-humidity transmitter for HVAC, equipment rooms, buildings and storage areas. Wall-mounted, duct-mounted and separate-probe arrangements are available with selected current, voltage or RS485/Modbus outputs and optional local LCD indication.
Humidity and Temperature Measurement
| Item | Specification |
|---|---|
| Humidity sensor | Digital |
| Humidity range | 0–100% RH |
| Humidity accuracy | ±3% RH at 20 °C and 20–80% RH |
| Humidity response time | ≤10 s at 20 °C in slowly moving air |
| Temperature sensor | Digital sensor or selected passive resistance element |
| Temperature range options | 0–50 °C or −20–60 °C; other ranges by confirmation |
| Digital temperature accuracy | ±0.3 °C from 0 to 60 °C |
| Mounting options | Wall, duct or separate probe |
Output and Power Supply
| Configuration | Signal | Supply |
|---|---|---|
| Current | 4–20 mA, two-wire | 19.5–35 VDC at 500 Ω; 9.5–35 VDC at 0 Ω |
| Voltage | 0–10 VDC, three-wire | 15–35 VDC or 24 VAC ±20% |
| Digital | RS485/Modbus | 15–35 VDC or 24 VAC ±20% |
Operating Conditions
| Item | Specification |
|---|---|
| Current output load | ≤500Ω |
| Voltage output load | ≥2kΩ |
| Operating environment | −20 to +60 °C; 5–95% RH, non-condensing |
| Protection | IP65 |
| Display | Optional LCD with units;4–20mA version without backlight |
| AC supply | Isolated supply required |
Passive Temperature Options
| Code | Element | Accuracy |
|---|---|---|
| 0 | Pt1000 | ±0.2 °C at 0 °C |
| 1 | Pt100 | ±0.2 °C at 0 °C |
| 2 | NTC20kΩ | ±0.4 °C at 25 °C |
| 6 | NTC10kΩ | ±0.4 °C at 25 °C |
Selection Fields
| Field | Options |
|---|---|
| Accuracy code | 3:±3% RH; temperature accuracy depends on sensor |
| Humidity output | V10:0–10VDC;A4:4–20mA;RS:RS485/Modbus |
| Temperature output | V10,A4,RS or selected passive element |
| Temperature range code | 0:none;1:0–50°C;2:−20–60°C;8:custom |
| Display code | 0:none;1:LCD |
Catalog Dimensions
| Configuration | Dimension | Value(mm) |
|---|---|---|
| Wall | Enclosure width/height/depth | 100/80/46 |
| Wall | Overall height | 169 |
| Wall | Probe diameter | 15 |
| Duct | Enclosure width/height/depth | 100/80/46 |
| Duct | Drawing probe length | 200 |
| Duct | Probe diameter | 15 |
| Separate probe | Enclosure width/height | 100/80 |
| Separate probe | Probe length/diameter | 213/15 |
Select mounting arrangement, humidity output, temperature output or passive sensor, calibrated temperature range and display. Analog temperature outputs require a range selection; digital and passive versions follow their own configuration. Specifications and dimensions shown follow the manufacturer’s individual LFH10 specification. Supply minima differ between document revisions; the listed current-output values use the higher minima in its technical table. Confirm the delivered version, load and wiring before connection. Use an isolated supply for AC operation. Maintain non-condensing conditions; prolonged exposure to concentrated chemical gases may cause sensor drift. The main photo shows the wall-mounted configuration. Other family configurations require separate specification confirmation.