Sensors & Instrumentation

Pitot Air Velocity Transmitter

Air velocity transmitter using an external pitot pickup and micro-pressure sensing for air or neutral gas. An LCD indicates the measured velocity, with a selected current, voltage or RS485 output for ventilation and process monitoring.

Air velocity transmitter using an external pitot pickup and micro-pressure sensing for air or neutral gas. An LCD indicates the measured velocity, with a selected current, voltage or RS485 output for ventilation and process monitoring.

Specifications below describe the LFS71 single-output configuration. The 0–40 m/s option requires an L-type pitot tube and is not established by the illustrated pickup.

Measurement and Operating Specifications

Item Specification
Medium Air or neutral gas
Measurement method Pressure-derived air velocity with external pitot pickup and MEMS micro-pressure sensing
Standard ranges 0–10, 0–20, 0–30 or 0–40 m/s
Accuracy ±3.0% FS for air velocity >3 m/s
Allowable overpressure 10 kPa
Host operating temperature −20 to +80 °C
Probe operating temperature −40 to +450 °C
Compensated temperature range −10 to +60 °C
Host storage temperature −40 to +85 °C
Response settings 0.5 s default; 1 s, 2 s or 4 s
Housing protection IP65
Display Digital LCD
Supply 12–30 VDC or 24 VAC ±20%
Power consumption ≤1.5 W
Housing material Cast aluminium
Host weight, approximate 1238 g

Range Selection

Code Range Condition
1 0–10 m/s Select compatible pickup
2 0–20 m/s Select compatible pickup
3 0–30 m/s Select compatible pickup
4 0–40 m/s L-type pitot tube only
X Custom Confirm required range and pickup

Single-Output Selection

Code Output
A 4–20 mA
B 0–10 VDC
C RS485; Modbus RTU

Host Dimensions

Item Value
Overall width shown 179 ±2 mm
Horizontal mounting spacing 124 ±1 mm
Overall height shown 168 ±2 mm
Vertical mounting spacing shown 144.7 ±1 mm
Side-view depth 92.5 ±1 mm
Body diameter shown 104 mm
Cable entry marking M20 ×1.5
Lower width shown 120 mm

Dimensions Drawing

LFS71 host and pickup dimensions

Ordering Information

Specify the LFS71 configuration, range code, single-output code and compatible pickup. Confirm the complete ordering designation, pressure connections and tubing for the application.

Select the velocity range, output and compatible pickup together. The 0–40 m/s range requires an L-type pitot tube; the illustrated pickup does not establish that option. The stated accuracy applies above 3 m/s. Keep the host within its own temperature range: the higher probe temperature rating does not apply to the transmitter enclosure. An isolated AC source is recommended when using AC power. Confirm pressure connection size and tubing before installation. Specifications and host drawing describe the single-output configuration; dual-output versions require their own code and dimensions. Hazardous-area suitability is not established by this product page.