Electronic vacuum regulators provide proportional control of negative pressure from an external electrical command. Select current, voltage or four-point preset input to suit the controller, with an analog monitor or switching output option.
The adjustable vacuum range is −1.3 to −80 kPa. An external vacuum source connects to VAC; OUT supplies the controlled vacuum circuit and ATM is the atmospheric port. This unit regulates supplied vacuum and does not generate vacuum by itself.
Vacuum and power specifications
| Parameter | Specification |
|---|---|
| Set vacuum range | −1.3 to −80 kPa |
| Required supply vacuum | Set vacuum −13.3 kPa or deeper, within the source limit |
| Maximum supply vacuum (catalog) | −101 kPa |
| 24 V version | 24 VDC ±10%; current ≤0.12 A |
| 12–15 V version | 12–15 VDC; current ≤0.18 A |
| Ambient and fluid temperature | 0–50 °C; no freezing |
Input and monitor options
| Option | Specification |
|---|---|
| Current input | 4–20 mA or 0–20 mA; input impedance ≤250 Ω |
| Voltage input | 0–5 VDC or 0–10 VDC; input impedance approximately 6.5 kΩ |
| Preset input | 4 points; common negative |
| Preset input impedance | 4.7 kΩ at 24 VDC; approximately 2 kΩ at 12 VDC |
| Voltage monitor | 1–5 VDC; load impedance approximately 1 kΩ |
| Current monitor | 4–20 mA, sink; load impedance ≤250 Ω |
| Analog monitor accuracy | Within ±6% full scale |
| NPN switch output | Open collector; maximum 30 V, 80 mA |
| PNP switch output | Open collector; maximum 80 mA |
Control performance
| Parameter | Catalog specification |
|---|---|
| Linearity | Within ±1% full scale |
| Hysteresis | ≤0.5% full scale |
| Repeatability | Within 0.5% full scale |
| Sensitivity | ≤0.2% full scale |
| Temperature characteristic | Within ±0.12% full scale per °C |
| Display accuracy | Within ±2% full scale ±1 digit |
| Display unit | kPa; minimum increment 1 |
Connections and dimensions
| Feature | Specification |
|---|---|
| VAC vacuum-source port | 1/4 |
| ATM and OUT ports | 2 × 1/4 |
| Thread options | Rc standard; NPT, NPTF or G optional |
| Atmosphere introduction port | M5 × 0.8 |
| Electrical connector thread | M12 × 1 |
| Body height shown in drawing | 99 mm, excluding bracket and cable connector |
| Port center height from body base | 19 mm |
| Mounting threads | 4 × M5 × 0.8; 6 mm thread depth |
| Mounting center spacing | 36 × 36 mm |
| Flat bracket envelope | 100 × 52 mm; 1.6 mm plate thickness |
| L bracket width and projection | 50 mm width; 45 mm projection; 2.3 mm thickness |
Cable and bracket selection
| Feature | Options |
|---|---|
| Cable connection | Straight 3 m or right-angle 3 m |
| Mounting accessory | No bracket, flat bracket or L bracket |
| Monitor selection | Choose analog or switching output; outputs are alternatives |
| Power wiring | Separate DC supply required; two-wire 4–20 mA operation is not supported |
| Supply preparation | Do not install a lubricator on the supply side |
Choose the supply voltage, input signal, monitor output, thread type, bracket and cable configuration when ordering. Current input requires a separate DC supply. The listed monitor outputs are alternatives. Confirm the electrical configuration before wiring; the four-point preset option uses two switching inputs and a common negative.
Vacuum values above are gauge-pressure values. For example, a −50 kPa setpoint requires a supply vacuum of −63.3 kPa or deeper, within the −101 kPa catalog limit. Do not use a supply-side lubricator.
Connections and installation dimensions
Dimensions are in millimetres. Original drawing identifiers are retained for traceability; select the actual bracket and thread option before installation.

Mounting brackets