Dimensions and Structure

Outline B

Outline B dimensions

Plug-In Straight Fitting
A straight plug-in adapter joining a push-in tube connection to an insertion stem. Select the tube diameter, stem diameter and required outline from the matching dimension table.
Outline A dimensions (mm)
| Tube OD D | Stem OD D1 | D2 | L1 | L2 |
|---|---|---|---|---|
| 4 | 6 | 10 | 16 | 35 |
| 4 | 8 | 10 | 13 | 34 |
| 6 | 8 | 12 | 15.5 | 36 |
| 6 | 10 | 12 | 16.8 | 41 |
| 8 | 10 | 14 | 17.5 | 42 |
| 6 | 12 | 12 | 13.5 | 38.5 |
| 8 | 12 | 14 | 17.5 | 42.5 |
| 10 | 12 | 17 | 21 | 46 |
Outline B dimensions (mm)
| Stem OD D | Tube OD D1 | D2 | L1 | L2 |
|---|---|---|---|---|
| 6 | 4 | 11 | 20 | 36.5 |
| 8 | 4 | 11 | 22 | 36.5 |
| 8 | 6 | 13 | 22 | 39 |
| 10 | 6 | 13 | 24.5 | 38.5 |
| 10 | 8 | 14.5 | 24.5 | 44 |
| 12 | 6 | 13 | 26.5 | 39.5 |
| 12 | 8 | 14.5 | 26.5 | 43 |
| 12 | 10 | 18.5 | 26.5 | 50 |
Operating specifications
| Item | Specification |
|---|---|
| Fluid | Air and vacuum |
| Positive operating pressure | 0–1.0 MPa |
| Operating temperature | 5–60 °C |
| Applicable tubing | Polyurethane and nylon |
Outline A and Outline B are drawing references, not ordering codes. They use different dimension symbols: Outline A has D at the tube connection and D1 at the stem; Outline B has D1 at the tube connection and D at the stem. L1 also follows its own drawing. Do not mix dimensions between outlines. Dimensions are in millimetres. A numerical vacuum limit and cross-brand retention compatibility are not specified.