Dimensions and Structure

Air Compressor Pressure Switch with Thermal Overload Protection
Pressure-operated motor control for air compressors and water pumps, combined with a thermal overload relay. The switch starts and stops the motor at preset pressure limits. A manual rotary knob provides shut-off, while the selected unloader helps the compressor restart without load.
Pressure Selection
| Adjustment range (bar) | Differential range (bar) | Factory cut-in / cut-out (bar) |
|---|---|---|
| 1–6 | 0.7–2 | 2 / 3 |
| 3–11 | 1.5–3.5 | 6 / 8 |
| 6–16 | 2–7 | 9 / 12 |
| 5–25 | 3–8 | 16 / 20 |
| 12–35 | 3–8 | 25 / 30 |
Technical Specifications
| Item | Specification |
|---|---|
| Medium | Water, air |
| Contact arrangement | Multi-pole single-throw, normally closed |
| Fluid temperature | −40 to +82 °C |
| Enclosure protection | IP54 |
| Cable size | 10–14 AWG |
| Contact material | Silver alloy, fixed and moving contacts |
| Thermal relay restart | Allow 30 minutes for cooling |
| Motor cycle interval | More than 5 minutes |
Electrical Rating Options
| Supply | Catalog rating options |
|---|---|
| Single phase | 120 V AC / 10 A; 230 V AC / 10 A |
| Three phase | 120 V AC / 10 A; 230 V AC / 10 A |
| Three phase | 400 V AC / 7.5 A or 11 A |
| Three phase | 500 V AC / 6 A or 9 A |
| Three phase | 690 V AC / 4.5 A or 6.5 A |
Ordering Field B: Female Pressure Ports
| Code | Connection |
|---|---|
| 1 | G1/4 + 3 × G1/4 |
| 2 | R1/4 + 3 × R1/4 |
| 3 | 1/4 NPT + 3 × 1/4 NPT |
| 4 | G3/8 + 3 × G1/4 |
| 5 | R3/8 + 3 × R1/4 |
| 6 | 3/8 NPT + 3 × 1/4 NPT |
| 7 | G1/2 + 3 × G1/4 |
| 8 | R1/2 + 3 × R1/4 |
| 9 | 1/2 NPT + 3 × 1/4 NPT |
Ordering Field C: Unloader
| Code | Option |
|---|---|
| 1 | No unloader |
| 2 | Vertical M12, brass |
| 3 | Vertical Ø6 tube push-in, brass |
| 4 | Vertical oil-resistant M12, brass |
| 5 | Vertical oil-resistant Ø6 tube push-in, brass |
| 6 | Vertical oil-resistant M12, zinc alloy |
| 7 | Horizontal oil-resistant M12, zinc alloy |
Other Ordering Fields
| Field | Code | Selection |
|---|---|---|
| A | 1 | Four-port body |
| D | 1 | No unloading function |
| D | 2 | Tube outside diameter 6.0–6.1 mm |
| D | 3 | Tube outside diameter 6.4–6.5 mm |
| E | 1 | Adjustable current 2.5–4 A |
| E | 2 | Adjustable current 4–6.3 A |
| E | 3 | Adjustable current 6.3–10 A |
| E | 4 | Adjustable current 10–16 A |
| E | 5 | Adjustable current 16–20 A |
Drawing Dimensions
| Drawing feature | Dimension (mm) |
|---|---|
| Top-view overall length | 110 |
| Top-view overall width | 82 |
| Top-view inner width | 71 |
| Height to top of manual knob | 103 |
| Housing reference height | 92 |
| Lower connection region height | 50 |
| Connection spacing shown | 58.5 |
| Offset shown | 30 |
Select the pressure range and cut-in/cut-out settings, then specify ordering fields A–E for body, ports, unloader, tube connection and current adjustment. The selected thermal relay must suit the motor current and the switch electrical rating. Ratings are configuration-dependent; the listed current ranges do not mean every supply/rating combination is available. Dimensions are in millimetres and refer to the illustrated configuration.