Capsule Low Pressure Gauges
Capsule-element gauges provide local indication of low positive and negative gas pressure. Select the dial size, scale, connection position and thread for the installation.
Operating Specifications
| Parameter | Specification / options |
|---|---|
| Measuring principle | Capsule element |
| Application | Low positive and negative gas pressure; boiler ventilation, gas piping and combustion equipment |
| Suitable media | Non-explosive gases that do not corrode copper or copper alloy |
| Dial size options | 50, 63, 100 and 150 mm |
| Accuracy options | 2.5% for 50, 63, 100 and 150 mm; 1.5% option for 100 and 150 mm |
| Scale units | kPa, mbar, mmH2O or mmHg |
| Range selection | Specify the required positive, negative or compound scale when ordering; illustrated gauge: 0–600 mbar, class 2.5 |
| Connection position | Lower (radial) or back (axial) |
| Protection options | IP40 or IP54, depending on configuration |
| Ambient temperature | −20 to +60 °C |
| Humidity | Not more than 80% |
Connection Selection
| Dial size | Thread options |
|---|---|
| 50 / 63 mm | M14×1.5, G1/4 or NPT1/4 |
| 100 / 150 mm | M20×1.5, G1/2 or NPT1/2 |
Construction Options
| Component | Specification / options |
|---|---|
| Dial / pointer | White aluminium dial / black aluminium pointer |
| Case | Steel for 63, 100 and 150 mm; stainless steel option for 100 and 150 mm |
| Ring | 63 mm: inset glass without ring; 100 / 150 mm: bayonet ring |
| Movement / capsule | Stainless steel or brass |
| Process connection | Stainless steel or brass |
| Window | Instrument glass |
Options depend on the selected configuration and are not supplied together as standard. Confirm the required range, accuracy, protection level, materials and mounting dimensions before ordering. The photograph illustrates a 0–600 mbar, class 2.5 gauge.