DODOMACH PNEUMATIC

Accessories

Double Universal Male Elbow

Double Universal Male Elbow with 2 push-in tube ports, R or G male-thread options, and listed metric tube sizes from 4 to 12 mm.

Category

Dimensions and Structure

Double Universal Male Elbow dimensions

R tapered-thread version

Double universal male elbow with R tapered thread

R tapered-thread dimensions

R tapered-thread dimensions

Double Universal Male Elbow

A stacked male elbow fitting with 2 push-in tube connections for distributing pneumatic tubing from one threaded connection. Select a listed tube diameter and the required R tapered or G parallel thread.

G parallel-thread dimensions (mm)

Tube OD D (2 ports) E B P (2 ports) A G thread H
4 24 38.5 13 5.5 G1/8 11
6 24 38.5 13 5.5 G1/8 11
6 25.5 42 13 6.5 G1/4 15
8 28 42 15 6.5 G1/4 15
8 30 52.5 15 7.5 G3/8 19
10 33 52.5 18.5 7.5 G3/8 19
10 35 57 21 9.5 G1/2 22
12 33.5 52.5 21 7.5 G3/8 19
12 35 57 21 9.5 G1/2 22

R tapered-thread dimensions (mm)

Tube OD D R thread L1 L2 L3 L4 L5 D1 Wrench size
4 R1/8 7.5 14 15 38 23.5 11.5 12
4 R1/4 9.5 16.5 15 41.5 25.5 11.5 14
6 R1/8 7.5 14 15 38 23.5 13.5 12
6 R1/4 9.5 16.5 15 41.5 25.4 13.5 14
6 R3/8 10.5 18.5 15.7 49.5 29.5 13.5 19
8 R1/8 7.5 14.5 15 38 26.5 15 12
8 R1/4 9.5 17.5 15 41.5 29 15 14
8 R3/8 10.5 18.5 15.7 49.5 30 15 19
8 R1/2 13.5 25.5 21.5 60 32.5 15 24
10 R1/8 7.5 18 19 44 30.5 19 12
10 R1/4 9.5 18.5 21.5 44.8 32.5 19 14
10 R3/8 10.5 20.5 21.5 53 33 19 19
10 R1/2 13.5 25.5 21.5 60 36 19 24
12 R1/4 9.5 18.5 21.5 44.8 33.5 21.5 14
12 R3/8 10.5 22 21.5 53 35.5 21.5 19
12 R1/2 13.5 25.5 21.5 60 36.5 21.5 24

Operating specifications

Item Specification
Fluid Air and vacuum
Positive operating pressure 0–1.0 MPa
Operating temperature 5–60 °C
Applicable tubing Polyurethane and nylon
Connections 2 push-in tube ports and one male threaded connection

All dimensions are in millimetres except thread designations. R and G versions have separate drawings and dimension tables; use the drawing for the selected thread. The quoted operating specifications apply to the listed fitting range. A numerical vacuum limit is not specified. The fitting is for pneumatic tube connection and positioning; continuous rotary service is not specified.