Dimensions and Structure

High-Pad T-Port Dimensions

High-Pad L-Port Dimensions

Modulating T-Port Dimensions

Modulating L-Port Dimensions

Electric Three-Way Brass Ball Valve
Electrically operated three-way brass ball valve for hot and cold water systems, with compact T-port and high-mounting-pad T-port or L-port configurations. The main photograph shows the compact actuator configuration.
Compact T-Port Configuration: Dimensions and Flow
| DN | Bore (mm) | Weight (g) | L (mm) | A (mm) | H (mm) | B (mm) | W (mm) | Kv |
|---|---|---|---|---|---|---|---|---|
| 15 | 10 | 462 | 55.4 | 71.3 | 115 | 42 | 63 | 7 |
| 20 | 13 | 606 | 68 | 71.3 | 119 | 53 | 63 | 10 |
| 25 | 17 | 728 | 76 | 71.3 | 123.5 | 59.5 | 63 | 15 |
| 32 | 25 | 1279 | 97.8 | 71.3 | 132 | 76 | 63 | 31 |
| 40 | 32 | 1931 | 118 | 71.3 | 139 | 93 | 63 | 39 |
| 50 | 38 | 2318 | 134 | 71.3 | 147 | 105 | 63 | 48 |
Compact Configuration: Materials and Service
| Parameter | Specification |
|---|---|
| Body, ball, cover and stem | Brass |
| Seal | NBR |
| Nominal pressure | 1.6 MPa |
| Medium | Hot or cold water; 50% ethylene glycol |
| Medium temperature | 5-95 C |
| Protection | IP54 |
Compact Configuration: Electrical Options
| Control option | Supply options |
|---|---|
| Three-wire, two-control | AC220V; AC110V; DC12V; DC24V; AC24V |
| Three-wire, one-control; normally open or normally closed | AC220V; AC110V; DC24V |
| Two-wire power-off return; normally open or normally closed | AC220V; DC12-24V; DC12V; DC24V |
High-Pad T-Port Configuration: Dimensions and Flow
| DN | Bore (mm) | L (mm) | A (mm) | H (mm) | B (mm) | W (mm) | Kv |
|---|---|---|---|---|---|---|---|
| 15 | 10 | 55.4 | 126 | 155 | 42 | 84 | 9 |
| 20 | 13 | 68.2 | 126 | 158 | 53 | 84 | 15 |
| 25 | 17 | 76 | 126 | 162 | 59.5 | 84 | 18 |
| 32 | 25 | 97.8 | 126 | 172 | 78 | 84 | 31 |
| 40 | 32 | 118 | 126 | 184 | 93 | 84 | 38 |
| 50 | 38 | 134 | 126 | 186 | 105 | 84 | 48 |
High-Pad L-Port Configuration: Dimensions and Flow
| DN | Bore (mm) | L (mm) | A (mm) | H (mm) | B (mm) | W (mm) | Kv |
|---|---|---|---|---|---|---|---|
| 15 | 10 | 55.4 | 126 | 155 | 42 | 84 | 7 |
| 20 | 13 | 68.2 | 126 | 158 | 53 | 84 | 10 |
| 25 | 17 | 76 | 126 | 162 | 59.5 | 84 | 15 |
| 32 | 25 | 97.8 | 126 | 172 | 78 | 84 | 31 |
| 40 | 32 | 118 | 126 | 184 | 93 | 84 | 39 |
| 50 | 38 | 134 | 126 | 186 | 105 | 84 | 48 |
High-Pad Configuration: Service and Actuation
| Parameter | Specification |
|---|---|
| Body, ball, cover and stem | Brass |
| Nominal pressure | 1.6 MPa |
| Medium | Hot or cold water; 50% ethylene glycol |
| Medium temperature | 5-95 C |
| Three-wire control with manual operation | AC220V; AC110V; DC12V; DC24V; AC24V; AC380V |
| Two-wire power-off return option | DC12V |
| Actuation time | 5-15 seconds |
| Rotation | 0-90 degrees |
| Protection | IP67 |
| Output torque | 30 N m |
Modulating T-Port Configuration: Dimensions and Flow
| DN | Bore (mm) | L (mm) | A (mm) | H (mm) | B (mm) | W (mm) | Kv |
|---|---|---|---|---|---|---|---|
| 15 | 10 | 55.4 | 126 | 123 | 42 | 84 | 9 |
| 20 | 13 | 68.2 | 126 | 126 | 53 | 84 | 15 |
| 25 | 17 | 76 | 126 | 130 | 59.5 | 84 | 18 |
| 32 | 25 | 97.8 | 126 | 140 | 76 | 84 | 31 |
| 40 | 32 | 118 | 126 | 152 | 93 | 84 | 38 |
| 50 | 38 | 134 | 126 | 154 | 105 | 84 | 48 |
Modulating L-Port Configuration: Dimensions and Flow
| DN | Bore (mm) | L (mm) | A (mm) | H (mm) | B (mm) | W (mm) | Kv |
|---|---|---|---|---|---|---|---|
| 15 | 10 | 55.4 | 126 | 123 | 42 | 84 | 7 |
| 20 | 13 | 68.2 | 126 | 126 | 53 | 84 | 10 |
| 25 | 17 | 76 | 126 | 130 | 59.5 | 84 | 15 |
| 32 | 25 | 97.8 | 126 | 140 | 76 | 84 | 31 |
| 40 | 32 | 118 | 126 | 152 | 93 | 84 | 39 |
| 50 | 38 | 134 | 126 | 154 | 105 | 84 | 48 |
Modulating Configuration: Service
| Parameter | Specification |
|---|---|
| Body, ball, cover and stem | Brass |
| Nominal pressure | 1.6 MPa |
| Medium | Hot or cold water; 50% ethylene glycol |
| Medium temperature | 5-95 C |
Modulating Configuration: Actuator Technical Data
| Parameter | Specification |
|---|---|
| Control type in technical table | Three-position floating |
| Supply in actuator technical table | AC24V; AC220V; DC24V |
| Frequency | 50/60 Hz |
| Torque | 24 N m |
| Running time | 15-20 seconds |
| Running power | 3.6 W |
| Standby power | 0.1 W |
| Control signal in technical table | Switching; three-wire or six-wire |
| Position indication | Valve position indicator |
| Rotation | 0-90 degrees |
| Rated-load life stated in source | 80000 rotations |
| Noise | Less than 45 dB |
| Protection class | II |
| Enclosure protection | IP65 |
| Ambient temperature | -10 to 50 C |
| Ambient humidity | 5-95% RH |
| Storage temperature | -30 to 60 C |
Dimensions and flow coefficients are configuration-specific. Select the matching T-port or L-port table; values must not be transferred between actuator configurations. DN65 dimensions are not specified in the source tables and are not included. High-pad and modulating seal materials are not stated here because the source descriptions conflict.
