Electronic proportional vacuum control from −1.3 to −80 kPa, with 1/4 ports, digital display and selectable current, voltage or four-point preset input. Choose 24 VDC or 12–15 VDC power, monitor output and mounting accessories.

Category

Electronic vacuum regulators provide proportional control of negative pressure from an external electrical command. Select current, voltage or four-point preset input to suit the controller, with an analog monitor or switching output option.

The adjustable vacuum range is −1.3 to −80 kPa. An external vacuum source connects to VAC; OUT supplies the controlled vacuum circuit and ATM is the atmospheric port. This unit regulates supplied vacuum and does not generate vacuum by itself.

Vacuum and power specifications

Parameter Specification
Set vacuum range −1.3 to −80 kPa
Required supply vacuum Set vacuum −13.3 kPa or deeper, within the source limit
Maximum supply vacuum (catalog) −101 kPa
24 V version 24 VDC ±10%; current ≤0.12 A
12–15 V version 12–15 VDC; current ≤0.18 A
Ambient and fluid temperature 0–50 °C; no freezing

Input and monitor options

Option Specification
Current input 4–20 mA or 0–20 mA; input impedance ≤250 Ω
Voltage input 0–5 VDC or 0–10 VDC; input impedance approximately 6.5 kΩ
Preset input 4 points; common negative
Preset input impedance 4.7 kΩ at 24 VDC; approximately 2 kΩ at 12 VDC
Voltage monitor 1–5 VDC; load impedance approximately 1 kΩ
Current monitor 4–20 mA, sink; load impedance ≤250 Ω
Analog monitor accuracy Within ±6% full scale
NPN switch output Open collector; maximum 30 V, 80 mA
PNP switch output Open collector; maximum 80 mA

Control performance

Parameter Catalog specification
Linearity Within ±1% full scale
Hysteresis ≤0.5% full scale
Repeatability Within 0.5% full scale
Sensitivity ≤0.2% full scale
Temperature characteristic Within ±0.12% full scale per °C
Display accuracy Within ±2% full scale ±1 digit
Display unit kPa; minimum increment 1

Connections and dimensions

Feature Specification
VAC vacuum-source port 1/4
ATM and OUT ports 2 × 1/4
Thread options Rc standard; NPT, NPTF or G optional
Atmosphere introduction port M5 × 0.8
Electrical connector thread M12 × 1
Body height shown in drawing 99 mm, excluding bracket and cable connector
Port center height from body base 19 mm
Mounting threads 4 × M5 × 0.8; 6 mm thread depth
Mounting center spacing 36 × 36 mm
Flat bracket envelope 100 × 52 mm; 1.6 mm plate thickness
L bracket width and projection 50 mm width; 45 mm projection; 2.3 mm thickness

Cable and bracket selection

Feature Options
Cable connection Straight 3 m or right-angle 3 m
Mounting accessory No bracket, flat bracket or L bracket
Monitor selection Choose analog or switching output; outputs are alternatives
Power wiring Separate DC supply required; two-wire 4–20 mA operation is not supported
Supply preparation Do not install a lubricator on the supply side

Choose the supply voltage, input signal, monitor output, thread type, bracket and cable configuration when ordering. Current input requires a separate DC supply. The listed monitor outputs are alternatives. Confirm the electrical configuration before wiring; the four-point preset option uses two switching inputs and a common negative.

Vacuum values above are gauge-pressure values. For example, a −50 kPa setpoint requires a supply vacuum of −63.3 kPa or deeper, within the −101 kPa catalog limit. Do not use a supply-side lubricator.

Connections and installation dimensions

Dimensions are in millimetres. Original drawing identifiers are retained for traceability; select the actual bracket and thread option before installation.

Electronic vacuum regulator connections and dimensions

Mounting brackets

Electronic vacuum regulator bracket dimensions