DODOMACH PNEUMATIC

Air Source Treatment (F.R.L.)

Float-Piloted Automatic Condensate Drains

Float-piloted automatic drains for compressed-air condensate. Operating pressure 0.15–1.0 MPa, with Rc (PT) 1/2 inlet and Rc (PT) 3/8 drain. Supplied with a bowl guard.

Dimensions and operating structure

Float-piloted automatic condensate drain dimensions and operating structure

Automatic condensate discharge

A float-piloted drain for compressed-air systems. As condensate rises, the float opens a pilot passage and pressure moves the piston to discharge accumulated liquid. A bowl guard is supplied as standard.

Operating specifications

Parameter Specification
Fluid Compressed-air condensate
Operation Float-piloted, pressure-operated automatic drain
Operating pressure 0.15–1.0 MPa
Ambient and fluid temperature 5–60°C
Inlet connection Rc (PT) 1/2
Drain connection Rc (PT) 3/8
Body outside diameter 82 mm
Overall height shown 184 mm
Lower fitting width shown 22 mm

Installation requirements

Item Requirement
Drain tube inside diameter At least 10 mm
Drain tube length No more than 5 m
Tube routing Do not route upward
Compressor power Greater than 3.7 kW