High Platform Three Way Flanged Ball Valve
Three flanged connections and a raised mounting platform provide a compact arrangement for flow diversion or distribution. L-port and T-port ball configurations are available. The main image shows the bare-stem mounting arrangement; handle or actuator dimensions depend on the selected assembly.
Dimensions
Class 150 configuration. Dimensions in mm. Bolt holes are shown as quantity-diameter. Values apply only to the configuration shown; confirm mating flanges and the selected assembly before ordering.
| DN | L | D | D1 | D2 | b | f | Bolt holes |
|---|---|---|---|---|---|---|---|
| 15 | 108 | 90 | 60.3 | 34.9 | 11.5 | 1.6 | 4-16 |
| 20 | 117 | 100 | 69.9 | 42.9 | 13 | 1.6 | 4-16 |
| 25 | 127 | 110 | 79.5 | 50.8 | 14.5 | 1.6 | 4-16 |
| 32 | 140 | 115 | 88.9 | 63.5 | 16 | 1.6 | 4-16 |
| 40 | 165 | 125 | 98.4 | 73 | 17.5 | 1.6 | 4-16 |
| 50 | 178 | 150 | 120.7 | 92.1 | 19.5 | 1.6 | 4-19 |
| 65 | 190 | 180 | 139.7 | 104.8 | 22.5 | 1.6 | 4-19 |
| 80 | 203 | 190 | 152.4 | 127 | 24 | 1.6 | 4-19 |
| 100 | 229 | 230 | 190.5 | 157.2 | 24 | 1.6 | 8-19 |
| 125 | 356 | 255 | 215.9 | 185.7 | 24 | 1.6 | 8-23 |
| 150 | 394 | 280 | 241.3 | 215.9 | 25.5 | 1.6 | 8-23 |
Additional sizes require a confirmed dimensional drawing.
Material Options
| Part | Material options |
|---|---|
| Body and bonnet | A216 WCB, A351 CF8 or A351 CF8M |
| Ball | A276 304 or A276 316 |
| Stem | 2Cr13, A276 304 or A276 316 |
| Seat | PTFE or RPTFE |
| Packing | PTFE or flexible graphite |
| Gland | A216 WCB or A351 CF8 |
| Bolt | A193 B7 or A193 B8M |
| Nut | A194 2H or A194 8 |
Materials are configuration alternatives, not interchangeable combinations. Select body, trim, seals and packing for the actual medium, pressure and temperature.
Configuration
| Item | Configuration |
|---|---|
| Connection | Three flanged ports |
| Mounting | Raised mounting platform; bare stem shown |
| Flow path | L-port or T-port |
| Dimensional configuration | Class 150 |
| Published dimension range | DN15-DN150 |
Flow Paths

Confirm the required port arrangement and operating positions when specifying the valve.