Accumulator stop valve with a hydraulically balanced conical main valve and dedicated oil-drain connection.
Function and Connections
The main shut-off valve isolates the accumulator from the hydraulic system. A separate drain valve provides the oil-return path for releasing hydraulic pressure. S connects to the accumulator, P to the system and T to the tank return.
Ordering Information
The XJF series uses a welded-flange P-port connection. Select the main nominal diameter: 10, 20, 32, 40 or 50 mm. The suffix /10 identifies the 10 mm drain diameter. The supplier also lists XJ1F with a male-thread P port; the dimensions below are for the listed XJF models and must not be assumed to apply to XJ1F.
Specifications
| Model | Nominal diameter (mm) | Nominal pressure (MPa) | Nominal flow (L/min) | Drain diameter (mm) | Matching accumulator capacity (L) |
|---|---|---|---|---|---|
| XJF-10/10 | 10 | 31.5 | 40 | 10 | 1.6-6.3 |
| XJF-20/10 | 20 | 31.5 | 100 | 10 | 1.6-6.3 |
| XJF-32/10 | 32 | 31.5 | 160 | 10 | 10-100 |
| XJF-40/10 | 40 | 31.5 | 250 | 10 | 10-100 |
| XJF-50/10 | 50 | 31.5 | 400 | 10 | 10-100 |
Dimensions
| Model | Nominal diameter | A | A1 | B | B1 | B2 | B3 | L | L1 | L2 | D1 | D2 | H | Dp | Ds |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XJF-10/10 | 10 | 64 | 185 | 58 | 67 | 163 | 15 | 244 | 15 | 148 | 125 | 90 | 9 | 18.5 | M42x2 |
| XJF-20/10 | 20 | 64 | 185 | 58 | 67 | 163 | 15 | 244 | 15 | 148 | 125 | 90 | 10 | 28.5 | M42x2 |
| XJF-32/10 | 32 | 85 | 226 | 76 | 68 | 197 | 18.5 | 295/299 | 26/30 | 175 | 160 | 90 | 16 | 43 | M60x2/M72x2 |
| XJF-40/10 | 40 | 90 | 235 | 90 | 68 | 205 | 18.5 | 364/368 | 26/30 | 229 | 160 | 90 | 18 | 52 | M60x2/M72x2 |
| XJF-50/10 | 50 | 110 | 278 | 110 | 68 | 215 | 18.5 | 386 | 30 | 233 | 200 | 90 | 20 | 62 | M60x2/M85x2 |
Dimensions are in millimetres except thread specifications. Slash-separated values are catalog alternatives; confirm the selected connection and corresponding dimensions before ordering.