Nitrogen charging cart for bladder, piston and diaphragm accumulators and other compatible high-pressure vessels. A hydraulically piloted reversing system drives a reciprocating booster. Select the output-pressure configuration for the required application.
Working Principle
The hydraulic pilot reversing valve drives a reciprocating booster. Nitrogen is drawn from the bottle into one gas chamber while the opposite chamber delivers compressed nitrogen to the accumulator. An electrical-contact pressure gauge signals the hydraulic system to stop when the preset pressure is reached.
Ordering Information
CDZ identifies the nitrogen charging cart. Select 25, 35 or 42 for the maximum charging pressure in MPa; Y1 identifies hydraulic pilot reversing. Specify the complete model and the actual required charging pressure. Electrical supply and connection details must be confirmed for the selected unit.
Specifications
| Model | Nitrogen inlet pressure (MPa) | Maximum output pressure (MPa) | Oil-pump pressure (MPa) | Oil-pump flow (L/min) | Booster pressure ratio | Boost cycles per minute |
|---|---|---|---|---|---|---|
| CDZ-25Y1 | 3.0-13.5 | 25 | 7 | 9 | 1:6 | 8 |
| CDZ-35Y1 | 3.0-13.5 | 35 | 7 | 9 | 1:6 | 8 |
| CDZ-42Y1 | 3.0-13.5 | 42 | 8 | 14-16 | 1:7 | 7 |
Dimensions and Listed Accessories
| Item | Catalog specification |
|---|---|
| Overall size (L x W x H) | 800 x 600 x 1500 mm |
| Charging-tool hose | 3000 mm |
| Nitrogen-source hose | 1500 mm |
Schematic Key
| Item | Component |
|---|---|
| 1 | Fluid filter |
| 2 | Vane pump |
| 3 | Check valve |
| 4 | Pilot reversing valve |
| 5 | Upper vent valve |
| 6 | Gas valve assembly |
| 7 | Electrical-contact pressure gauge |
| 8 | Relief valve |
| 9 | Hydraulic pressure gauge |
| 10 | Lower vent valve |
| 11 | Bidirectional booster |
| 12 | Charging pressure gauge |
Use and Selection
Use nitrogen only. Oxygen and other flammable or corrosive gases are prohibited. The maximum output pressure depends on the selected model and is not the required charging setting for every accumulator. Confirm the permitted pressure of the accumulator and all connected accessories before use.