Dimensions and Structure

Plug-In Y Fitting
A plug-in Y fitting with two push-in tube connections and one insertion stem. Equal and reducing tube-to-stem combinations are listed separately for pneumatic tube distribution.
Dimensions (mm)
| D tube | D1 stem | D2 | D3 mounting hole | L1 | L2 | L3 | L4 |
|---|---|---|---|---|---|---|---|
| 4 | 4 | 11.5 | 3.2 | 52.5 | 33.5 | 14.5 | 11 |
| 6 | 6 | 13.5 | 3.2 | 53.8 | 34.8 | 15 | 13 |
| 8 | 8 | 15 | 3.2 | 57.8 | 37.3 | 18 | 15 |
| 10 | 10 | 19 | 4.2 | 71 | 46.5 | 21 | 18 |
| 12 | 12 | 21.5 | 4.2 | 75.5 | 49.5 | 21.5 | 21 |
| 4 | 6 | 11.5 | 3.2 | 52.8 | 33.8 | 14.5 | 11 |
| 6 | 8 | 13.5 | 3.2 | 55.5 | 35 | 15 | 13 |
| 8 | 10 | 15 | 3.2 | 62 | 37.3 | 18 | 15 |
| 10 | 12 | 19 | 4.2 | 72.5 | 46.5 | 21 | 18 |
Operating specifications
| Item | Specification |
|---|---|
| Fluid | Air and vacuum |
| Positive operating pressure | 0–1.0 MPa |
| Operating temperature | 5–60 °C |
| Applicable tubing | Polyurethane and nylon |
Dimensions are in millimetres. D identifies the two tube ports and D1 identifies the insertion stem; select both sizes from the same table row. D3 is the mounting-hole diameter. The listed range uses polyurethane or nylon tubing. A numerical vacuum limit and cross-brand retention compatibility are not specified.