Pneumatically Controlled Air Shut-Off Valves
Normally open, two-port air shut-off valve operated by a pneumatic pilot signal. Intended for controlling the compressed-air supply in vacuum-generation circuits, with a separate pneumatic vacuum switch providing the control signal.
The valve switches the air path; it does not measure the vacuum threshold. The source circuit pairs this normally open valve with an NC pneumatic-output vacuum switch. Select the components and connect the numbered ports according to the corresponding circuit.
Dimensions and switching symbol

| Selection | Normal state | Control | Supply pressure (bar) | Temperature (C) | Mass (g) |
|---|---|---|---|---|---|
| NO | Normally open | Pneumatic | 1 to 8 | 0 to 60 | 55 |
Connection and dimensional selection
| Feature | Specification |
|---|---|
| Threaded connection | G1/8 male |
| Push-in tubing | 8 mm diameter |
| Overall length | 76 mm |
| Body width | 25 mm |
| Reserved pilot connections | 3 positions, 3 mm diameter; see original drawing |
The 1 to 8 bar range is the source supply-pressure specification, not a separately verified pilot switching-pressure range. Flow coefficient, allowable leakage, pilot switching pressure and service life are not specified. Actual air savings depend on the complete vacuum circuit and application; no savings percentage is assigned to the valve.