Dimensions and Structure

Six-Way Push-In Tube Union
A six-way push-in tube union with two axial connections and four branch connections for distributing air or water. Choose the axial and branch tube diameters from the dimensional table.
Operating Specifications
| Item | Specification |
|---|---|
| Fluid | Air or water |
| Operating pressure | -100 kPa to 1 MPa |
| Proof pressure | 1.5 MPa at 23 °C |
| Air temperature | -5 to 60 °C; no freezing |
| Water temperature | 0 to 40 °C; no freezing |
| Applicable tubing | Polyurethane, nylon, soft nylon |
| Connections | 2 axial ports (a) and 4 branch ports (b) |
Model and Dimensions (mm)
| Supplier model | Tube OD a | Tube OD b | D1 | D2 | L1 | L2 | M1 | M2 | P | Mass (g) |
|---|---|---|---|---|---|---|---|---|---|---|
| PHD8-4 | 8 | 4 | 13.8 | 12.7 | 89 | 26.5 | 17.2 | 14.8 | 16 | 42.5 |
| PHD8-6 | 8 | 6 | 13.8 | 12.7 | 89 | 24.9 | 17.2 | 16 | 16 | 55.5 |
| PHD8-8 | 8 | 8 | 13.8 | 14.8 | 89 | 26.9 | 17.2 | 17.4 | 16 | 39.6 |
| PHD10-6 | 10 | 6 | 16.8 | 17.5 | 104.7 | 32 | 19.4 | 15.2 | 19 | 67.4 |
| PHD10-8 | 10 | 8 | 16.8 | 17.5 | 104.7 | 30.2 | 19.4 | 14.6 | 19 | 58.4 |
| PHD10-10 | 10 | 10 | 16.8 | 17.8 | 104.7 | 30.8 | 19.4 | 20 | 19 | 60.7 |
Dimensions are in millimetres. The drawing identifies two axial ports as a and four branch ports as b. Keep surge pressure below the maximum operating pressure. Do not use for leak testing or vacuum retention. Continuous rotary operation is not specified. Listed ratings and dimensions apply to the supplier configurations shown.