Rotary Electric Operation
Electric actuator with manual handwheel, clutch mechanism, position indication, torque and limit switching, and mechanical travel stops. A double worm-gear transmission drives the output shaft. The mounting base supports vertical or horizontal installation.
110-120 N.m
| Supply | Motor power (W) | Rated current (A) | Output torque (N.m) | Standard operating time (s) |
|---|---|---|---|---|
| DC 24 V | 28 | 6 | 110 | 15 |
| AC 24 V | 30 | 5.2 | 110 | 22 |
| AC 110 V | 30 | 0.96 | 110 | 22 |
| AC 220 V | 30 | 0.46 | 120 | 22 |
| AC 380 V | 30 | 0.4 | 120 | 22 |
Reference weight: 13 kg.
200-220 N.m
| Supply | Motor power (W) | Rated current (A) | Output torque (N.m) | Standard operating time (s) |
|---|---|---|---|---|
| DC 24 V | 45 | 7.5 | 200 | 15 |
| AC 24 V | 45 | 6.8 | 220 | 24 |
| AC 110 V | 50 | 1.32 | 220 | 24 |
| AC 220 V | 50 | 0.52 | 220 | 24 |
| AC 380 V | 50 | 0.28 | 220 | 24 |
Reference weight: 17 kg.
400 N.m
| Supply | Motor power (W) | Rated current (A) | Output torque (N.m) | Standard operating time (s) |
|---|---|---|---|---|
| DC 24 V | 90 | 9.2 | 400 | 15 |
| AC 24 V | 90 | 8.5 | 400 | 25 |
| AC 110 V | 90 | 2.4 | 400 | 25 |
| AC 220 V | 90 | 0.98 | 400 | 25 |
| AC 380 V | 90 | 0.56 | 400 | 25 |
Reference weight: 20 kg.
600 N.m
| Supply | Motor power (W) | Rated current (A) | Output torque (N.m) | Standard operating time (s) |
|---|---|---|---|---|
| DC 24 V | 120 | 11 | 600 | 15 |
| AC 24 V | 120 | 9.6 | 600 | 29 |
| AC 110 V | 120 | 3 | 600 | 29 |
| AC 220 V | 120 | 1.12 | 600 | 29 |
| AC 380 V | 120 | 0.6 | 600 | 29 |
Reference weight: 21 kg.
800-1000 N.m
| Supply | Motor power (W) | Rated current (A) | Output torque (N.m) | Standard operating time (s) |
|---|---|---|---|---|
| DC 24 V | 200 | 13 | 800 | 18 |
| AC 24 V | 200 | 11.8 | 1000 | 33 |
| AC 110 V | 200 | 3.8 | 1000 | 33 |
| AC 220 V | 200 | 1.83 | 1000 | 33 |
| AC 380 V | 200 | 0.82 | 1000 | 33 |
Reference weight: 30 kg.
2000 N.m AC configuration
| Supply | Motor power (W) | Rated current (A) | Output torque (N.m) | Standard operating time (s) |
|---|---|---|---|---|
| DC 24 V | 200 | 14 | Not confirmed | 45 |
| AC 24 V | 200 | 12.5 | 2000 | 85 |
| AC 110 V | 200 | 4.5 | 2000 | 85 |
| AC 220 V | 200 | 2.1 | 2000 | 85 |
| AC 380 V | 200 | 0.9 | 2000 | 85 |
Reference weight: 60 kg.
Operating Specifications
| Parameter | Specification |
|---|---|
| Protection options | IP65 / IP67, according to configuration |
| Rotation angle options | 0-90, 0-180, 0-270 or 0-360 degrees |
| AC supply frequency | 50 / 60 Hz |
| Supply tolerance | +/-10% |
| Ambient temperature | -20 to +60 degrees C |
| Ambient humidity | Maximum 90% RH at 25 degrees C, non-condensing |
| Altitude | Up to 1000 m |
| Duty | Short-time operation, 10 minutes |
| Insulation resistance | 100 MOhm at 500 V DC |
| Dielectric test | 1800 V AC for 1 minute |
| Mounting interface | ISO 5211 |
| Installation orientation | Vertical or horizontal |
Explosion-proof configuration must be selected to match the installation environment. Confirm the supplied unit marking and applicable certification before installation in a hazardous location. Non-explosion-proof configurations must not be used in explosive gas environments.
Overall Height (mm)
| Configuration | Height |
|---|---|
| 110-120 N.m | 233.5 |
| 200-220 N.m | 270 |
| 400 / 600 N.m | 322 |
| 800-1000 N.m | 322 |
| 2000 N.m AC configuration | 503 |