DODOMACH PNEUMATIC

FLUID VALVE

Explosion Proof Rotary Electric Actuator

Categories ,

Rotary electric actuator structure views

Rotary Electric Operation

Electric actuator with manual handwheel, clutch mechanism, position indication, torque and limit switching, and mechanical travel stops. A double worm-gear transmission drives the output shaft. The mounting base supports vertical or horizontal installation.

110-120 N.m

Supply Motor power (W) Rated current (A) Output torque (N.m) Standard operating time (s)
DC 24 V 28 6 110 15
AC 24 V 30 5.2 110 22
AC 110 V 30 0.96 110 22
AC 220 V 30 0.46 120 22
AC 380 V 30 0.4 120 22

Reference weight: 13 kg.

200-220 N.m

Supply Motor power (W) Rated current (A) Output torque (N.m) Standard operating time (s)
DC 24 V 45 7.5 200 15
AC 24 V 45 6.8 220 24
AC 110 V 50 1.32 220 24
AC 220 V 50 0.52 220 24
AC 380 V 50 0.28 220 24

Reference weight: 17 kg.

400 N.m

Supply Motor power (W) Rated current (A) Output torque (N.m) Standard operating time (s)
DC 24 V 90 9.2 400 15
AC 24 V 90 8.5 400 25
AC 110 V 90 2.4 400 25
AC 220 V 90 0.98 400 25
AC 380 V 90 0.56 400 25

Reference weight: 20 kg.

600 N.m

Supply Motor power (W) Rated current (A) Output torque (N.m) Standard operating time (s)
DC 24 V 120 11 600 15
AC 24 V 120 9.6 600 29
AC 110 V 120 3 600 29
AC 220 V 120 1.12 600 29
AC 380 V 120 0.6 600 29

Reference weight: 21 kg.

800-1000 N.m

Supply Motor power (W) Rated current (A) Output torque (N.m) Standard operating time (s)
DC 24 V 200 13 800 18
AC 24 V 200 11.8 1000 33
AC 110 V 200 3.8 1000 33
AC 220 V 200 1.83 1000 33
AC 380 V 200 0.82 1000 33

Reference weight: 30 kg.

2000 N.m AC configuration

Supply Motor power (W) Rated current (A) Output torque (N.m) Standard operating time (s)
DC 24 V 200 14 Not confirmed 45
AC 24 V 200 12.5 2000 85
AC 110 V 200 4.5 2000 85
AC 220 V 200 2.1 2000 85
AC 380 V 200 0.9 2000 85

Reference weight: 60 kg.

Operating Specifications

Parameter Specification
Protection options IP65 / IP67, according to configuration
Rotation angle options 0-90, 0-180, 0-270 or 0-360 degrees
AC supply frequency 50 / 60 Hz
Supply tolerance +/-10%
Ambient temperature -20 to +60 degrees C
Ambient humidity Maximum 90% RH at 25 degrees C, non-condensing
Altitude Up to 1000 m
Duty Short-time operation, 10 minutes
Insulation resistance 100 MOhm at 500 V DC
Dielectric test 1800 V AC for 1 minute
Mounting interface ISO 5211
Installation orientation Vertical or horizontal

Explosion-proof configuration must be selected to match the installation environment. Confirm the supplied unit marking and applicable certification before installation in a hazardous location. Non-explosion-proof configurations must not be used in explosive gas environments.

Overall Height (mm)

Configuration Height
110-120 N.m 233.5
200-220 N.m 270
400 / 600 N.m 322
800-1000 N.m 322
2000 N.m AC configuration 503