Dimensions and Structure

Industrial Pressure Transmitter
Compact industrial gauge-pressure transmitter for water systems, air compressors, pneumatic equipment and factory automation. Select a pressure span, current or voltage output, or RS485 interface, with the appropriate supply and electrical connection. The specifications below describe the LFT2010 catalog configuration.
Output Selection
| Code | Output | Wiring | Supply | Accuracy note |
|---|---|---|---|---|
| A4 | 4–20 mA | Two-wire | 10–36 VDC | See accuracy specification |
| V0 | 0–5 V | Three-wire | 10–36 VDC | Zero-point accuracy 0.25% FS |
| V10 | 0–10 V | Three-wire | 14–30 VDC | Zero-point accuracy 0.25% FS |
| RS | RS485 | Four-wire | 10–30 VDC | Protocol not specified in selected catalog |
Specifications
| Item | Value |
|---|---|
| Pressure reference | Gauge pressure |
| Range selection | Zero-based ranges with full-scale values from 0.1 to 4 MPa; specify required span |
| Overload | 1.5 times rated pressure |
| Accuracy | ±0.1% FS at 25 °C including linearity, repeatability and hysteresis; voltage-output zero-point exception applies |
| Stability | <0.1% FS/year |
| Operating temperature | −20 to +85 °C |
| Storage temperature | −40 to +100 °C |
| Medium | Gas or liquid compatible with 304 and 316L stainless steel and selected FKM or NBR seals |
| Protection | IP54 for GX12 connectors; IP65 for DIN43650A, M12 cable outlet and M12 connector |
Electrical Connections
| Code | Connection |
|---|---|
| D1 | DIN43650A |
| M | M12 waterproof cable outlet |
| C3 | GX12 three-core connector |
| C4 | GX12 four-core connector |
| H | M12 four-core connector |
Pressure Connection Codes
| Code | Connection |
|---|---|
| G | G1/4 |
| G2 | G1/2 |
| N | NPT1/4 |
| M20 | M20×1.5 |
| R | R1/4 |
| M2 | M12×1 |
Dimensions
| Electrical version | Height (mm) | Body diameter (mm) | Wrench size (mm) | Illustrated process port |
|---|---|---|---|---|
| M12 cable outlet | 92±2 | 26.6 | 27 | G1/4 |
| DIN43650A | 110±2 | 26.6 | 27 | G1/4 |
| GX12 connector | 128±2 | 26.6 | 27 | G1/4 |
| M12 connector | 141±2 | 26.6 | 27 | G1/4 |
Catalog reference: LFT2010. Selection fields: pressure range, unit, output, accuracy, electrical connection, pressure connection and cable length. Unit codes: K = kPa, M = MPa, P = psi and B = bar. Cable-length choices are 1, 2 or 3 m where applicable. Accuracy is specified at 25 °C; the 0–5 V and 0–10 V versions have a 0.25% FS zero-point accuracy exception. Confirm the RS485 protocol for the selected unit. The photograph shows the DIN43650A version. Drawing dimensions are in millimetres; from left to right the original diagrams show the M12 cable outlet, DIN43650A, GX12 and M12 connector versions. Dimensions shown use G1/4; other process connections must be confirmed.