LFT2020 — 50.5 mm clamp connection Dimensions and Structure

LFT2700 — G1/2 threaded connection Dimensions and Structure

Product Configuration Photographs
LFT2020 cooling-fin clamp version, RS485

LFT2700 threaded version

Flush Diaphragm Pressure Transmitter
Flush-diaphragm pressure transmitters for viscous liquids and media that may block a recessed pressure port. Select a 50.5 mm clamp connection or a G1/2 threaded connection, with model-specific analogue or RS485 output options. The flush sensing face supports access for cleaning.
Model and Process Connection Selection
| Catalog reference | Process connection | Measurement structure | Suitable application |
|---|---|---|---|
| LFT2020 | K2:50.5 mm clamp | Oil-filled diffused-silicon, flush diaphragm | Accessible clamp connection for process pressure measurement |
| LFT2700 | G:G1/2 threaded | Diffused-silicon, flush diaphragm | Viscous media where recessed pressure ports may clog |
Catalog Operating Specifications
| Item | LFT2020 | LFT2700 |
|---|---|---|
| Pressure reference | Gauge G or absolute A | Gauge G or absolute A |
| Catalog range selection | −100 kPa…0 to 10 kPa…6 MPa | −100 kPa…0 to 20 kPa…35 MPa |
| Overload | 1.5 times rated pressure | 1.5 times rated pressure |
| Accuracy | ±0.5% FS technical rating; 1.0% option also listed in order table, confirm configuration | ±0.5% FS or ±1.0% FS at 25 °C, including linearity, repeatability and hysteresis |
| Stability | <0.5% FS/year | <0.5% FS/year |
| Ambient working temperature | −20 to +85 °C | −20 to +85 °C |
| Medium temperature | −40 to +100 °C or −40 to +150 °C, depending on temperature version; confirm selection | −40 to +100 °C |
| Medium compatibility | 316L stainless steel and selected sealing ring | 304/316L stainless steel and selected FKM or NBR seals |
| Protection | IP54 GX12; IP65 DIN43650A, M12 cable/connector and M20 cable outlet | IP54 GX12; IP65 DIN43650A, M12 cable/connector and M20 cable outlet |
Standard Non-Display Output Selection
| Model | Code | Output | Wiring | Catalog supply |
|---|---|---|---|---|
| LFT2020 | A4 | 4–20 mA | Two-wire | 8–36 VDC |
| LFT2020 | V05 | 0.5–4.5 V | Three-wire | 4.75–5.25 VDC |
| LFT2020 | V10 | 0–10 V | Three-wire | 12–36 VDC |
| LFT2020 | RS | RS485 | Four-wire | 10–30 VDC |
| LFT2700 | A4 | 4–20 mA | Two-wire | 8–36 VDC |
| LFT2700 | V05 | 0.5–4.5 V | Three-wire | 4.75–5.25 VDC |
| LFT2700 | V0 | 0–5 V | Three-wire | 8–36 VDC |
| LFT2700 | V10 | 0–10 V | Three-wire | 12–36 VDC |
| LFT2700 | RS | RS485 | Four-wire | 10–30 VDC |
Electrical Connection Codes
| Code | Connection |
|---|---|
| D1 | DIN43650A angular connector |
| M | M12 waterproof cable outlet |
| C3 | GX12 three-core connector |
| C4 | GX12 four-core connector |
| H | M12 four-core connector |
Basic Non-Display Dimensions
| Model | Electrical connection | Height (mm) | Body diameter (mm) | Process connection |
|---|---|---|---|---|
| LFT2020 | DIN43650A standard | 105±3 | 26.6 | Clamp diameter 50.5 mm |
| LFT2020 | DIN43650A cooling-fin version | 128±3 | 26.6 | Clamp diameter 50.5 mm |
| LFT2700 | M12 cable outlet | 94±2 | 26.6 | G1/2 |
| LFT2700 | DIN43650A | 112±2 | 26.6 | G1/2 |
| LFT2700 | GX12 connector | 130±2 | 26.6 | G1/2 |
| LFT2700 | M12 connector | 143±2 | 26.6 | G1/2 |
Ordering Options
| Field | Codes and meaning |
|---|---|
| Pressure unit | K:kPa; M:MPa; P:psi; B:bar |
| Accuracy code | 0.5:0.5% FS; 1.0:1.0% FS; confirm model-specific rating |
| Display | N:no display; D1:conventional display; display power differs from non-display version |
| Cable length | LFT2020:1 or 2 m; LFT2700:1,2 or3 m, where applicable |
Catalog references: LFT2020 (clamp) and LFT2700 (threaded). The range notation describes available calibrated ranges; it is not one adjustable span. Specify pressure reference and required range when ordering. Tables reproduce the selected supplier catalog version; confirm the current configuration, particularly LFT2020 range and supply. LFT2020 V0 output appears in the order list but its supply is not specified there and is not included in the confirmed output table. Conventional-display LFT2700 uses DIN43650A and12–30VDC per the catalog footnote. Confirm other display supplies and the RS485 protocol separately. The main photograph shows the LFT2020 cooling-fin version with RS485 output; it does not represent every option. Original drawings include display and enclosure variants for dimensional reference; the drawings do not establish hazardous-area certification. Dimensions are in millimetres. No interchangeability with another brand is claimed.