Dimensions and Structure

Combined Pressure and Temperature Transmitter
Compact combined transmitter with a piezoresistive pressure sensor and Pt100 temperature sensor in one housing. It monitors both pressure and temperature in compatible gas or liquid systems, with selected current, voltage or RS485 output configurations for water treatment and industrial process monitoring.
Measurement Specifications
| Item | Value |
|---|---|
| Measured variables | Pressure and temperature |
| Pressure sensor | Piezoresistive |
| Temperature sensor | Pt100 |
| Pressure range selection | Zero-based spans with full scale from 10 kPa to 70 MPa |
| Temperature measurement range | −20 to +100 °C |
| Pressure accuracy | ±0.5% FS |
| Temperature accuracy | ±2% FS |
| Accuracy basis | At 25 °C; includes linearity, repeatability and hysteresis |
| Overload | 1.5 times rated pressure |
| Stability | <0.5% FS/year |
| Working temperature | −20 to +85 °C |
| Pressure reference | Gauge (G) or absolute (A) |
| Medium | Gases or liquids compatible with 304/316L stainless steel and selected FKM or NBR seals |
Output and Supply Options
| Code | Signal option | Supply |
|---|---|---|
| A4 | 4–20 mA | 10–30 VDC |
| V05 | 0.5–4.5 V | 4.75–5.25 VDC |
| RS | RS485 | 10–30 VDC |
Electrical Connections
| Code | Connection | Catalog protection |
|---|---|---|
| D1 | DIN43650A angular connector | IP65 |
| M | M12 waterproof cable outlet | IP65 |
| C3 | GX12 three-core connector | IP54 |
| C4 | GX12 four-core connector | IP54 |
| H | M12 four-core connector | IP65 |
Process Connections
| Thread | Catalog selection code |
|---|---|
| G1/4 | G |
| G1/2 | G2 |
| NPT1/4 | N |
| M20×1.5 | M20 |
| M10×1 | Confirm code for selected catalog revision |
| M12×1 | M12 |
Other Selection Fields
| Field | Selection |
|---|---|
| Pressure unit | K: kPa; M: MPa; P: psi; B: bar |
| Pressure accuracy code | 0.5 |
| Temperature accuracy code | 2 |
| Cable length | 1.0: 1 m; 2.0: 2 m; 3.0: 3 m where applicable |
Catalog reference: LFT3100. Select both measuring ranges, output configuration, accuracy, electrical connector, pressure connection and cable length. Confirm the pressure and temperature channel assignments and complete wiring diagram for the selected connector before connection; the output table is not a universal pinout. Intelligent RS485 versions support Modbus according to the manufacturer; confirm the protocol settings and register map for the delivered unit. The original drawings show multiple enclosure variants, with dimensions in millimetres; confirm the relevant drawing for the ordered configuration. The photograph shows one DIN43650A version. Confirm medium and storage temperature limits separately because source editions use different labels. No hazardous-area certification or international-brand interchangeability is claimed.