Wafer-type vortex flowmeter for liquid, gas or steam applications. An LCD displays instantaneous and accumulated flow, with optional temperature compensation and selectable analogue or digital outputs.
Specifications describe the LFLUGB wafer-type family. Liquid, gas and steam applications require their matching configuration and operating conditions.
Measurement and Operating Specifications
| Item | Specification |
|---|---|
| Principle | Vortex flow measurement |
| Media | Liquid, gas or steam; select matching configuration |
| Nominal diameter range | DN20–DN600 |
| Installation | Wafer-type mounting between flanges |
| Accuracy | 1.5% FS |
| Ambient temperature | −10 to +60 °C |
| Power consumption | ≤0.5 W |
| Enclosure protection | IP65 |
| Display | LCD; instantaneous and cumulative flow |
| Electrical entry | M20 ×1.5 female; custom option available |
Medium and Compensation Selection
| Field | Code | Option |
|---|---|---|
| Medium | 1 | Liquid |
| Medium | 2 | Gas |
| Medium | 3 | Steam |
| Temperature compensation | 1 | Without |
| Temperature compensation | 2 | With |
| Flange material | 1 | 304 stainless steel |
| Flange material | 2 | 316 stainless steel |
Power and Output Selection
| Field | Code | Option |
|---|---|---|
| Power | 1 | 3.6 V battery; integral version |
| Power | 2 | 24 VDC; integral version |
| Power | 3 | 220 VAC; remote version |
| Output | 1 | 4–20 mA |
| Output | 2 | RS485 |
| Output | 3 | 4–20 mA with HART |
| Output | 4 | 4–20 mA with RS485 |
| Output | 5 | No signal output |
Pressure Selection
| Code | Nominal pressure |
|---|---|
| 1 | 1.6 MPa |
| 2 | 2.5 MPa |
| 3 | 4.0 MPa |
Drawing Reference
| Marking | Description |
|---|---|
| Ø104 | Transmitter head diameter:104 mm |
| 125 | Transmitter head height shown:125 mm |
| H; L1; L2 | Overall height and axial dimensions; size-specific values required |
| D1; D2; D3; N | Flange geometry and mounting-hole reference; size-specific values required |
Dimensional Reference Drawing
Ordering Information
Specify the LFLUGB family, medium, nominal diameter, pressure, temperature compensation, material, power and output codes. Confirm the complete ordering designation and supported power/output combination.
Select the medium, nominal diameter, pressure rating, compensation, power and output together. Confirm the flow range, flow units and process temperature limits for the actual operating pressure and temperature before ordering. Ambient limits apply to the surrounding air. Battery power and all listed outputs are not assumed to be available in every combination. The drawing shows the instrument structure; obtain the dimensioned installation drawing for the selected size and pressure.