DODOMACH PNEUMATIC

Sensors & Instrumentation

Liquid Turbine Flowmeter

Integral turbine flowmeter for liquid flow monitoring, with flanged, threaded or clamp connections and selectable current or digital outputs. A battery-powered display-only configuration is also available.

Integral turbine flowmeter for liquid flow monitoring, with flanged, threaded or clamp connections and selectable current or digital outputs. A battery-powered display-only configuration is also available.

Specifications below describe the LFLWGY liquid configuration. The photograph shows the integral flanged version; other connections require their own installation dimensions.

Measurement and Operating Specifications

Item Specification
Principle Turbine liquid flow measurement
Nominal diameter family DN4–DN300; flow ranges listed separately
Stated accuracy 1.0%
Installation Integral transmitter
Connection options Flanged, pipe thread or clamp
Power options 24 VDC or battery version
Power consumption ≤0.5 W
Ambient temperature −10 to +60 °C
Standard fluid temperature −10 to +80 °C
Higher fluid temperatures Custom configurations up to100 or120 °C
Protection IP65
Stainless steel options 304 or316 housing; flange selection according to configuration

Liquid Flow Ranges

Nominal diameter Flow range (m³/h)
DN10 0.2–1.2
DN15 0.4–6
DN25 1.2–12
DN40 3–30
DN50 5–50
DN80 12–120
DN100 20–200
DN150 40–400
DN200 80–800
DN250 120–1200

Standard Diameter and Pressure

Diameter Listed nominal pressure
Up to DN200 1.6 MPa
DN250–DN300 1.0 MPa
Other pressures Custom confirmation required

Connection, Output and Power Selection

Field Code Option
Connection 1 Flanged
Connection 2 Pipe thread
Connection 3 Clamp
Output 1 4–20 mA
Output 2 RS485
Output 3 4–20 mA with RS485
Output 4 HART
Output 5 No signal output; battery version
Power 1 Battery
Power 2 24 VDC

Temperature and Housing Selection

Field Code Option
Fluid temperature 1 −10 to +80 °C
Fluid temperature 2 −10 to +100 °C; custom
Fluid temperature 3 −10 to +120 °C; custom
Housing 1 304 stainless steel
Housing 2 316 stainless steel

Dimensional Reference Drawing

Turbine flowmeter connection and dimension symbols

Ordering Information

Specify the LFLWGY liquid family, nominal diameter and flow range, pressure, connection code, output, power, fluid temperature and housing option. Confirm the complete ordering designation and compatible power/output combination.

Select nominal diameter from the required liquid flow range and verify the pressure, fluid properties and temperature for the chosen configuration. The table applies to liquid service; gas measurements require separate selection and calibration data. The stated 1.0% accuracy has no published reading/full-scale basis in the supplier sheet. Confirm output and power compatibility; battery operation is not assumed to support current or digital outputs. DN4 and DN300 flow limits require confirmation. Standard pressure ratings follow the diameter table; custom pressures require a configuration-specific rating. The structural drawings use dimension symbols; obtain numerical dimensions for the selected connection and size before installation.