Integral turbine flowmeter for liquid flow monitoring, with flanged, threaded or clamp connections and selectable current or digital outputs. A battery-powered display-only configuration is also available.
Specifications below describe the LFLWGY liquid configuration. The photograph shows the integral flanged version; other connections require their own installation dimensions.
Measurement and Operating Specifications
| Item | Specification |
|---|---|
| Principle | Turbine liquid flow measurement |
| Nominal diameter family | DN4–DN300; flow ranges listed separately |
| Stated accuracy | 1.0% |
| Installation | Integral transmitter |
| Connection options | Flanged, pipe thread or clamp |
| Power options | 24 VDC or battery version |
| Power consumption | ≤0.5 W |
| Ambient temperature | −10 to +60 °C |
| Standard fluid temperature | −10 to +80 °C |
| Higher fluid temperatures | Custom configurations up to100 or120 °C |
| Protection | IP65 |
| Stainless steel options | 304 or316 housing; flange selection according to configuration |
Liquid Flow Ranges
| Nominal diameter | Flow range (m³/h) |
|---|---|
| DN10 | 0.2–1.2 |
| DN15 | 0.4–6 |
| DN25 | 1.2–12 |
| DN40 | 3–30 |
| DN50 | 5–50 |
| DN80 | 12–120 |
| DN100 | 20–200 |
| DN150 | 40–400 |
| DN200 | 80–800 |
| DN250 | 120–1200 |
Standard Diameter and Pressure
| Diameter | Listed nominal pressure |
|---|---|
| Up to DN200 | 1.6 MPa |
| DN250–DN300 | 1.0 MPa |
| Other pressures | Custom confirmation required |
Connection, Output and Power Selection
| Field | Code | Option |
|---|---|---|
| Connection | 1 | Flanged |
| Connection | 2 | Pipe thread |
| Connection | 3 | Clamp |
| Output | 1 | 4–20 mA |
| Output | 2 | RS485 |
| Output | 3 | 4–20 mA with RS485 |
| Output | 4 | HART |
| Output | 5 | No signal output; battery version |
| Power | 1 | Battery |
| Power | 2 | 24 VDC |
Temperature and Housing Selection
| Field | Code | Option |
|---|---|---|
| Fluid temperature | 1 | −10 to +80 °C |
| Fluid temperature | 2 | −10 to +100 °C; custom |
| Fluid temperature | 3 | −10 to +120 °C; custom |
| Housing | 1 | 304 stainless steel |
| Housing | 2 | 316 stainless steel |
Dimensional Reference Drawing
Ordering Information
Specify the LFLWGY liquid family, nominal diameter and flow range, pressure, connection code, output, power, fluid temperature and housing option. Confirm the complete ordering designation and compatible power/output combination.
Select nominal diameter from the required liquid flow range and verify the pressure, fluid properties and temperature for the chosen configuration. The table applies to liquid service; gas measurements require separate selection and calibration data. The stated 1.0% accuracy has no published reading/full-scale basis in the supplier sheet. Confirm output and power compatibility; battery operation is not assumed to support current or digital outputs. DN4 and DN300 flow limits require confirmation. Standard pressure ratings follow the diameter table; custom pressures require a configuration-specific rating. The structural drawings use dimension symbols; obtain numerical dimensions for the selected connection and size before installation.