Adjustable Vacuum Switches with Pneumatic Output
Converts an adjustable vacuum threshold into a pneumatic control signal. Normally closed and normally open output versions are available for vacuum handling control circuits.
The adjustment screw sets the vacuum switching threshold. NC and NO identify pneumatic output states, not electrical contacts. Select the required state and vacuum range together.
Switching symbols and dimensions

| Selection | Pneumatic output | Supply pressure (bar) | Vacuum threshold (kPa gauge) | Differential (kPa) | Temperature (C) | Mass (g) |
|---|---|---|---|---|---|---|
| NC | Normally closed | 1.5 to 8 | -95 to -15 | 12 | -10 to 60 | 44 |
| NO | Normally open | 1.5 to 8 | -95 to -10 | 3 | -10 to 60 | 44 |
Connections and installation
| Feature | Specification |
|---|---|
| Vacuum connection | G1/8 male |
| Pneumatic tubing | 4 mm diameter |
| Mounting thread | M12x1 |
| Mounting holes | 2 holes, 3 mm diameter |
| Dimension labels in drawing | 17 mm, 55 mm and 60 mm |
Vacuum values are gauge pressures below atmospheric pressure. Differential is the switching hysteresis, not accuracy or repeatability. Follow the port numbers and NC/NO symbols in the drawing when connecting the circuit. Electrical voltage, current and enclosure ratings do not apply to this pneumatic output specification. Flow capacity, proof pressure and switching life are not specified in this sheet.