DODOMACH PNEUMATIC

Vacuum Units

Adjustable Vacuum Switches with Pneumatic Output

Converts an adjustable vacuum threshold into a pneumatic control signal. Normally closed and normally open output versions are available for vacuum handling control circuits.

Category

Adjustable Vacuum Switches with Pneumatic Output

Converts an adjustable vacuum threshold into a pneumatic control signal. Normally closed and normally open output versions are available for vacuum handling control circuits.

The adjustment screw sets the vacuum switching threshold. NC and NO identify pneumatic output states, not electrical contacts. Select the required state and vacuum range together.

Switching symbols and dimensions

Original NC and NO pneumatic switching symbols and mounting dimensions

Selection Pneumatic output Supply pressure (bar) Vacuum threshold (kPa gauge) Differential (kPa) Temperature (C) Mass (g)
NC Normally closed 1.5 to 8 -95 to -15 12 -10 to 60 44
NO Normally open 1.5 to 8 -95 to -10 3 -10 to 60 44

Connections and installation

Feature Specification
Vacuum connection G1/8 male
Pneumatic tubing 4 mm diameter
Mounting thread M12x1
Mounting holes 2 holes, 3 mm diameter
Dimension labels in drawing 17 mm, 55 mm and 60 mm

Vacuum values are gauge pressures below atmospheric pressure. Differential is the switching hysteresis, not accuracy or repeatability. Follow the port numbers and NC/NO symbols in the drawing when connecting the circuit. Electrical voltage, current and enclosure ratings do not apply to this pneumatic output specification. Flow capacity, proof pressure and switching life are not specified in this sheet.