Dimensions and Structure

Flanged Piston-Type Steam Pressure Reducing Valve
A flanged piston-type pressure reducing valve for steam service. Downstream pressure feedback adjusts the valve opening to regulate outlet pressure as inlet conditions change. The catalogue specifies horizontal installation.
Catalogue Dimensions (mm)
| Nominal size | Length L | Flange thickness B | Step diameter | Bolt circle diameter | Outside diameter | Step thickness f | Bolt holes: number-diameter |
|---|---|---|---|---|---|---|---|
| DN20 | 160 | 14 | 55 | 75 | 105 | 3 | 4-14 |
| DN25 | 180 | 14 | 65 | 85 | 115 | 3 | 4-14 |
| DN32 | 200 | 16 | 78 | 100 | 135 | 3 | 4-18 |
| DN40 | 220 | 16 | 85 | 110 | 145 | 3 | 4-18 |
| DN50 | 250 | 18 | 100 | 125 | 160 | 3 | 4-18 |
| DN65 | 280 | 18 | 120 | 145 | 180 | 3 | 4-18 |
| DN80 | 310 | 20 | 135 | 160 | 195 | 3 | 8-18 |
| DN100 | 350 | 20 | 155 | 185 | 215 | 3 | 8-18 |
| DN125 | 400 | 26 | 185 | 210 | 245 | 3 | 8-18 |
| DN150 | 450 | 30 | 210 | 240 | 280 | 3 | 8-23 |
| DN200 | 450 | 34 | 265 | 295 | 335 | 3 | 12-23 |
Selected Catalogue Performance Configurations
| Nominal pressure (MPa) | Strength test (MPa) | Sealing test (MPa) | Listed inlet pressure (MPa) | Outlet pressure (MPa) | Outlet pressure deviation (MPa) | Catalogue temperature limit |
|---|---|---|---|---|---|---|
| 1.6 | 2.4 | 1.76 | 0.25-1.6 | 0.05-1 | <= +/-0.05 | <=300 C |
| 4 | 6 | 4.4 | 4 / 3.3 / 2.8 | 0.1-2.5 | <= +/-0.07 | <=300 C |
| 6.4 | 9.6 | 7.04 | 6.4 / 5.2 / 2.9 | 0.1-3 | <= +/-0.07 | <=300 C |
Principal Materials
| Component | Catalogue material options |
|---|---|
| Body | WCB / FC / 304 |
| Valve core | 304 |
| Spring | Chrome-vanadium steel |
Dimensions are the catalogue reference table and are not assigned to a pressure class on this page. Confirm connection dimensions and pressure-temperature compatibility for the selected body material and configuration before ordering. The performance table lists selected catalogue configurations; separate inlet values are reproduced as listed, not converted into a continuous range. Test pressures are test values, not operating pressure limits.