Dimensions and Structure

Vertical Free Float Steam Trap
Designed for vertical inline installation with flow from top to bottom. A stainless steel free float controls condensate discharge. Air-vent arrangements vary by configuration. Suitable applications include steam mains, tracing lines, steam-heated equipment and condensate recovery systems.
Dimensions and Operating Parameters
| DN | Connection | Operating pressure (MPa) | PN | PMA (MPa) | TMA (C) | Body material | L (mm) | W (mm) | K (mm) |
|---|---|---|---|---|---|---|---|---|---|
| 15-25 | Female thread (Rc / NPT) | 0.01-1.6 | 25 | 1.7 | 260 | A105 | 120 | 110 | 16 |
| 15-25 | Socket weld (GB / ANSI) | 0.01-1.6 | 25 | 1.7 | 260 | A105 | 120 | 110 | 16 |
| 15-25 | Flanged (GB / ANSI / JIS) | 0.01-1.6 | 25 | 1.7 | 260 | A105 | 175 | 110 | 16 |
| 32-50 | Flanged (GB / ANSI / JIS) | 0.01-1.6 | 25 | 1.7 | 260 | A105 | 230 | 145 | Confirm |
| 15-25 | Female thread (Rc / NPT) | 0.01-1.6 | 40 | 2.7 | 371 | A105 | 210 | 147 | 15 |
| 15-25 | Female thread (Rc / NPT) | 0.1-4.5 | 63 | 4.7 | 371 | A105 | 230 | 176 | 21 |
| 15-25 | Socket weld (GB / ANSI) | 0.01-1.6 | 40 | 2.7 | 371 | A105 | 210 | 147 | 15 |
| 15-25 | Socket weld (GB / ANSI) | 0.1-4.5 | 63 | 4.7 | 371 | A105 | 230 | 176 | 21 |
| 15-50 | Flanged (GB / ANSI / JIS) | 0.01-1.6 | 40 | 2.7 | 371 | A105 | 270 | 147 | 15 |
| 15-50 | Flanged (GB / ANSI / JIS) | 0.1-4.5 | 63 | 4.7 | 371 | A105 | 270 | 176 | 21 |
| 15-25 | Female thread (Rc / NPT) | 0.01-1.6 | 40 | 2.7 | 371 | A105 | 300 | 200 | 30 |
| 15-25 | Female thread (Rc / NPT) | 0.1-4.5 | 110 | 5.8 | 427 | A105 | 300 | 265 | 30 |
| 15-25 | Socket weld (GB / ANSI) | 0.01-1.6 | 40 | 2.7 | 371 | A105 | 300 | 200 | 30 |
| 15-25 | Socket weld (GB / ANSI) | 0.1-4.5 | 110 | 5.8 | 427 | A105 | 300 | 265 | 30 |
| 15-50 | Flanged (GB / ANSI / JIS) | 0.01-1.6 | 40 | 2.7 | 371 | A105 | 320 | 200 | 30 |
| 15-50 | Flanged (GB / ANSI / JIS) | 0.1-4.5 | 110 | 5.8 | 427 | A105 | 400 | 265 | 30 |
Dimensions are in millimetres. PMA and TMA are the catalogue maximum allowable pressure and temperature entries, not a guarantee that both maxima apply simultaneously. Confirm the pressure-temperature rating, material, vent arrangement and connection standard for the selected configuration. The K dimension marked Confirm requires confirmation before ordering. Rows with the same DN are different configurations and are not interchangeable.
Materials
| Component / scope | Material |
|---|---|
| Body options in general material table | WCB / stainless steel |
| Body in dimension table configurations | A105 |
| Float | 304 stainless steel |
| Strainer | 304 stainless steel |