Measurement and Operating Specifications

Item Specification
Principle Vortex flow measurement
Media Liquid, gas or steam; select matching configuration
Nominal diameter range DN20–DN600
Installation Wafer-type mounting between flanges
Accuracy 1.5% FS
Ambient temperature −10 to +60 °C
Power consumption ≤0.5 W
Enclosure protection IP65
Display LCD; instantaneous and cumulative flow
Electrical entry M20 ×1.5 female; custom option available

Medium and Compensation Selection

Field Code Option
Medium 1 Liquid
Medium 2 Gas
Medium 3 Steam
Temperature compensation 1 Without
Temperature compensation 2 With
Flange material 1 304 stainless steel
Flange material 2 316 stainless steel

Power and Output Selection

Field Code Option
Power 1 3.6 V battery; integral version
Power 2 24 VDC; integral version
Power 3 220 VAC; remote version
Output 1 4–20 mA
Output 2 RS485
Output 3 4–20 mA with HART
Output 4 4–20 mA with RS485
Output 5 No signal output

Pressure Selection

Code Nominal pressure
1 1.6 MPa
2 2.5 MPa
3 4.0 MPa

Drawing Reference

Marking Description
Ø104 Transmitter head diameter:104 mm
125 Transmitter head height shown:125 mm
H; L1; L2 Overall height and axial dimensions; size-specific values required
D1; D2; D3; N Flange geometry and mounting-hole reference; size-specific values required

Dimensional Reference Drawing

Vortex flowmeter structural reference

Ordering Information

Specify the LFLUGB family, medium, nominal diameter, pressure, temperature compensation, material, power and output codes. Confirm the complete ordering designation and supported power/output combination.

Select the medium, nominal diameter, pressure rating, compensation, power and output together. Confirm the flow range, flow units and process temperature limits for the actual operating pressure and temperature before ordering. Ambient limits apply to the surrounding air. Battery power and all listed outputs are not assumed to be available in every combination. The drawing shows the instrument structure; obtain the dimensioned installation drawing for the selected size and pressure.