Technical Specifications
| Parameter | Specification |
|---|---|
| Operation | Electric actuator |
| Control configurations | Basic, integral or integral modulating |
| Standard power supply | Three-phase 380 V, 50 Hz |
| Optional three-phase supplies | 660 V or 415 V; 50 / 60 Hz |
| Optional single-phase supplies | 220 V or 110 V; 50 / 60 Hz |
| Standard ambient temperature | -20 to +60 C |
| Special ambient-temperature configuration | -40 to +80 C |
| Relative humidity | Up to 95% at 25 C |
| Standard enclosure protection | IP55 |
| Optional enclosure protection | IP65 or IP67 |
| Standard duty | Short-time operation, 10 minutes |
| Special duty option | 30 minutes |
Power supply, control function, enclosure protection and duty are selected configurations. Optional ratings are not simultaneous default specifications.