DODOMACH PNEUMATIC

Differential Pressure Transmitters

Electronic Differential Pressure Transmitter

Electronic differential pressure transmitters for air or neutral gas monitoring in HVAC, ventilation, filters and cleanrooms. Select compact, display, panel-mounted or industrial housing configurations with model-specific ranges and analog or digital outputs.

Dimensions and Model Identification

LFM108

DODOMACH LFM108 drawing DODOMACH LFM108 main

LFM11

DODOMACH LFM11 drawing DODOMACH LFM11 main

LFM52

DODOMACH LFM52 drawing DODOMACH LFM52 main

LFM55

DODOMACH LFM55 drawing DODOMACH LFM55 main

LFM751

DODOMACH LFM751 drawing DODOMACH LFM751 main

LFM76

DODOMACH LFM76 drawing DODOMACH LFM76 main

LFM77

DODOMACH LFM77 drawing DODOMACH LFM77 main

Electronic Differential Pressure Transmitter

Electronic differential pressure transmitters for air or neutral gas monitoring in HVAC, ventilation, filters and cleanrooms. Select compact, display, panel-mounted or industrial housing configurations with model-specific ranges and analog or digital outputs.

Model Selection

Catalog reference Range options (Pa) Accuracy Operating temperature (°C) Protection Output options
LFM108 ±100 / ±1000 / ±10000 ±1% FS −20 to +70 IP54 4–20 mA; 0–5 V; 0–10 V; RS485; combined voltage/RS485
LFM11 ±100 / ±1000 / ±10000 ±1% FS −10 to +60 IP54 4–20 mA; 0–5 V; 0–10 V; RS485; combined outputs
LFM52 ±100 / ±1000 / ±10000 ±1% FS −20 to +70 IP65 4–20 mA; 0–5 V; 0–10 V; RS485; combined current/voltage
LFM55 ±25 / ±50 / ±100 ±1 Pa −20 to +70 IP30 4–20 mA + 0–10 V; or RS485
LFM751 ±100 / ±1000 / ±10000 ±0.5% FS for range ≥500 Pa; ±1% FS below500 Pa −20 to +70 IP65 4–20 mA, two-wire
LFM76 ±100 / ±1000 / ±10000 ±1% FS −20 to +80 IP65 4–20 mA + RS485; 4–20 mA + 0–10 V; 0–10 V + RS485
LFM77 ±100 / ±1000 / ±10000 ±1% FS −20 to +80 IP65 4–20 mA; or 0–10 V; or RS485

Range Codes

Series Range code Range
LFM108 101G 0–100 Pa
LFM108 102G 0–1000 Pa
LFM108 103G 0–10000 Pa
LFM108 251G 0–250 Pa
LFM108 252G 0–2500 Pa
LFM108 501G 0–500 Pa
LFM108 502G 0–5000 Pa
LFM108 051D ±50 Pa
LFM108 101D ±100 Pa
LFM108 102D ±1000 Pa
LFM108 103D ±10000 Pa
LFM108 251D ±250 Pa
LFM108 252D ±2500 Pa
LFM108 501D ±500 Pa
LFM108 502D ±5000 Pa
LFM11 6 ±100 Pa
LFM11 0 ±1000 Pa
LFM11 2 ±10000 Pa
LFM52 6 ±100 Pa
LFM52 0 ±1000 Pa
LFM52 2 ±10000 Pa
LFM751 6 ±100 Pa
LFM751 0 ±1000 Pa
LFM751 2 ±10000 Pa
LFM76 1 ±100 Pa
LFM76 2 ±1000 Pa
LFM76 3 ±10000 Pa
LFM76 X Custom; confirm range
LFM77 1 ±100 Pa
LFM77 2 ±1000 Pa
LFM77 3 ±10000 Pa
LFM77 X Custom; confirm range
LFM55 1 ±25 Pa
LFM55 2 ±50 Pa
LFM55 3 ±100 Pa
LFM55 4 Custom; confirm range

Output Codes

Series Output code Signal
LFM108 AL 4–20 mA
LFM108 VL 0–10 VDC
LFM108 VZ 0–5 VDC
LFM108 MOD RS485
LFM108 MVL RS485 + 0–10 VDC
LFM108 MVZ RS485 + 0–5 VDC
LFM11 A 4–20 mA + 0–10 V simultaneously
LFM11 B 4–20 mA, two-wire, no backlight
LFM11 C 0–10 V, three-wire
LFM11 D 0–5 V, three-wire
LFM52 A 4–20 mA + 0–10 V simultaneously
LFM52 B 4–20 mA, two-wire, no backlight
LFM52 C 0–10 V, three-wire
LFM52 D 0–5 V, three-wire
LFM11 Confirm code RS485
LFM11 F 0–10 V + RS485
LFM52 E RS485
LFM52 E1 Isolated RS485
LFM55 A 4–20 mA + 0–10 V simultaneously
LFM55 E RS485
LFM751 Fixed 4–20 mA, two-wire
LFM76 A 4–20 mA + RS485
LFM76 B 4–20 mA + 0–10 V
LFM76 C 0–10 V + RS485
LFM77 A 4–20 mA
LFM77 B 0–10 V
LFM77 C RS485

Power Supply by Configuration

Series Configuration Supply
LFM108 4–20 mA / voltage / RS485 / voltage+RS485 10–30 / 16–30 / 12–30 / 16–30 VDC
LFM11 4–20 mA / voltage / RS485 / combined 12–30 / 16–30 / 12–30 / 16–30 VDC
LFM52 4–20 mA 12–30 VDC
LFM52 Voltage or current+voltage 12–30 VDC or 24 VAC ±20%
LFM52 RS485 9–30 VDC
LFM55 RS485 9–30 VDC or 24 VAC ±20%
LFM55 Current+voltage 12–30 VDC or 24 VAC ±20%
LFM751 4–20 mA 12–30 VDC
LFM76 / LFM77 Listed output configurations 12–30 VDC or 24 VAC ±20%

Envelope Dimensions

Series Width (mm) Height (mm) Depth (mm) Drawing notes
LFM108 97 overall; 90 body 87 35.5 M16 cable gland; Ø6.2 pressure ports
LFM11 90 105 overall; 80 body 44.5 M16 cable gland; Ø6.2 pressure ports
LFM52 100 103 overall; 80 body 46 M16 cable gland; Ø6.2 pressure ports
LFM55 110 100 33.5 overall; 31.5 behind panel Front panel dimensions; see drawing
LFM751 112 overall; 100 inner span 91 overall; 78 body 39 Grounding screw labelled in original drawing
LFM76 179±2 159±2 108±1 Mounting spans124±1 and136±1; M20×1.5
LFM77 179±2 168±2 92.5±1 Mounting spans124±1 and144.7±1; M20×1.5

Select the series, range, output and power supply together. Options and dimensions differ by model; the photographs do not imply identical configurations. LFM55 offers local audible and visual alarms. Confirm hazardous-area certification and installation requirements for the exact LFM751, LFM76 or LFM77 configuration before specifying hazardous-area service. For AC-powered LFM55/76/77 installations, the supplier recommends an isolated AC supply. LFM108 stability and overload limits and LFM751 overload limits require version-specific confirmation.

LFM751 drawing label: grounding screw. All drawing dimensions are in millimetres.