DODOMACH PNEUMATIC

Differential Pressure Transmitters

Wet/Wet Differential Pressure Transmitter

Process differential-pressure transmitter with two threaded pressure ports for compatible liquids or gases. Silicon piezoresistive sensing converts the pressure difference into a selected current, voltage or RS485 signal for process monitoring, hydraulic equipment and differential-pressure measurement systems.

Dimensions and Structure

Wet/Wet Differential Pressure Transmitter dimensions

Wet/Wet Differential Pressure Transmitter

Process differential-pressure transmitter with two threaded pressure ports for compatible liquids or gases. Silicon piezoresistive sensing converts the pressure difference into a selected current, voltage or RS485 signal for process monitoring, hydraulic equipment and differential-pressure measurement systems.

Differential Range and Accuracy

Selected differential full scale Accuracy at 25 °C
10 kPa to below 100 kPa ±0.5% FS
100 kPa Confirm selected accuracy; catalog intervals overlap at this boundary
Above 100 kPa to 3.5 MPa ±0.25% FS

Standard Output and Supply Selection

Code Output Wiring Catalog supply
A4 4–20 mA Two-wire 8–36 VDC
V05 0.5–4.5 V Three-wire 4.75–5.25 VDC
V0 0–5 V Three-wire 8–36 VDC
V10 0–10 V Three-wire 12–36 VDC
RS RS485 Four-wire 10–30 VDC

Operating Specifications

Item Value
Sensing principle Silicon piezoresistive differential pressure sensing
Pressure reference D:differential pressure
Range selection Zero-based differential spans with full scale from 10 kPa to 3.5 MPa
Overload 1.5 times rated pressure; not a stated common-mode/static line pressure rating
Stability <0.5% FS/year
Working temperature −10 to +60 °C
Storage temperature −40 to +100 °C
Medium Gas or liquid compatible with 304/316L stainless steel and selected FKM or NBR seals
Protection IP54 for GX12; IP65 for DIN43650A, M12 cable/connector and M20 cable outlet
Accuracy basis Measured at 25 °C; includes linearity, repeatability and hysteresis

Electrical Connections

Code Connection
D1 DIN43650A angular connector
M M12 waterproof cable outlet
C3 GX12 three-core connector
C4 GX12 four-core connector
H M12 four-core connector

Process Connection Codes

Code Connection
G G1/4
G2 G1/2
R R1/4
M20 M20×1.5
N NPT1/4

Dimensions of Illustrated DIN43650A Version

Height (mm) Port-to-port width (mm) Head width (mm) Wrench size (mm) Illustrated process ports
115±1 87 47±1 27 G1/2

Other Selection Fields

Field Selection
Unit K:kPa; M:MPa; P:psi; B:bar
Display N:no display; D1:conventional display; confirm display supply separately
Cable length 1,2 or 3 m where applicable

Catalog reference: LFT2050. Select differential range, unit, output, accuracy, electrical connection, process connection, display and cable length. Tables follow the selected supplier catalog; confirm the current configuration and supply before ordering. At 100 kPa full scale the catalog accuracy intervals overlap, so the selected accuracy must be confirmed. The 1.5-times overload figure must not be used as a static line-pressure rating; confirm the permitted pressure at each port for the application. The sample photograph is a 0–100 kPa, 0–10 V configuration and does not establish every option. Confirm the RS485 protocol separately. Original drawings include display/enclosure variants for reference; no hazardous-area certification is claimed. Dimensions are in millimetres; the dimension table applies to the illustrated DIN43650A version with G1/2 ports.