Process differential-pressure transmitter with two threaded pressure ports for compatible liquids or gases. Silicon piezoresistive sensing converts the pressure difference into a selected current, voltage or RS485 signal for process monitoring, hydraulic equipment and differential-pressure measurement systems.
Differential Range and Accuracy
| Selected differential full scale | Accuracy at 25 °C |
|---|---|
| 10 kPa to below 100 kPa | ±0.5% FS |
| 100 kPa | Confirm selected accuracy; catalog intervals overlap at this boundary |
| Above 100 kPa to 3.5 MPa | ±0.25% FS |
Standard Output and Supply Selection
| Code | Output | Wiring | Catalog supply |
|---|---|---|---|
| A4 | 4–20 mA | Two-wire | 8–36 VDC |
| V05 | 0.5–4.5 V | Three-wire | 4.75–5.25 VDC |
| V0 | 0–5 V | Three-wire | 8–36 VDC |
| V10 | 0–10 V | Three-wire | 12–36 VDC |
| RS | RS485 | Four-wire | 10–30 VDC |
Operating Specifications
| Item | Value |
|---|---|
| Sensing principle | Silicon piezoresistive differential pressure sensing |
| Pressure reference | D:differential pressure |
| Range selection | Zero-based differential spans with full scale from 10 kPa to 3.5 MPa |
| Overload | 1.5 times rated pressure; not a stated common-mode/static line pressure rating |
| Stability | <0.5% FS/year |
| Working temperature | −10 to +60 °C |
| Storage temperature | −40 to +100 °C |
| Medium | Gas or liquid compatible with 304/316L stainless steel and selected FKM or NBR seals |
| Protection | IP54 for GX12; IP65 for DIN43650A, M12 cable/connector and M20 cable outlet |
| Accuracy basis | Measured at 25 °C; includes linearity, repeatability and hysteresis |
Electrical Connections
| Code | Connection |
|---|---|
| D1 | DIN43650A angular connector |
| M | M12 waterproof cable outlet |
| C3 | GX12 three-core connector |
| C4 | GX12 four-core connector |
| H | M12 four-core connector |
Process Connection Codes
| Code | Connection |
|---|---|
| G | G1/4 |
| G2 | G1/2 |
| R | R1/4 |
| M20 | M20×1.5 |
| N | NPT1/4 |
Dimensions of Illustrated DIN43650A Version
| Height (mm) | Port-to-port width (mm) | Head width (mm) | Wrench size (mm) | Illustrated process ports |
|---|---|---|---|---|
| 115±1 | 87 | 47±1 | 27 | G1/2 |
Other Selection Fields
| Field | Selection |
|---|---|
| Unit | K:kPa; M:MPa; P:psi; B:bar |
| Display | N:no display; D1:conventional display; confirm display supply separately |
| Cable length | 1,2 or 3 m where applicable |
Catalog reference: LFT2050. Select differential range, unit, output, accuracy, electrical connection, process connection, display and cable length. Tables follow the selected supplier catalog; confirm the current configuration and supply before ordering. At 100 kPa full scale the catalog accuracy intervals overlap, so the selected accuracy must be confirmed. The 1.5-times overload figure must not be used as a static line-pressure rating; confirm the permitted pressure at each port for the application. The sample photograph is a 0–100 kPa, 0–10 V configuration and does not establish every option. Confirm the RS485 protocol separately. Original drawings include display/enclosure variants for reference; no hazardous-area certification is claimed. Dimensions are in millimetres; the dimension table applies to the illustrated DIN43650A version with G1/2 ports.