Dimensions and Model Identification
LFM108
LFM11
LFM52
LFM55
LFM751
LFM76
LFM77
Electronic Differential Pressure Transmitter
Electronic differential pressure transmitters for air or neutral gas monitoring in HVAC, ventilation, filters and cleanrooms. Select compact, display, panel-mounted or industrial housing configurations with model-specific ranges and analog or digital outputs.
Model Selection
| Catalog reference | Range options (Pa) | Accuracy | Operating temperature (°C) | Protection | Output options |
|---|---|---|---|---|---|
| LFM108 | ±100 / ±1000 / ±10000 | ±1% FS | −20 to +70 | IP54 | 4–20 mA; 0–5 V; 0–10 V; RS485; combined voltage/RS485 |
| LFM11 | ±100 / ±1000 / ±10000 | ±1% FS | −10 to +60 | IP54 | 4–20 mA; 0–5 V; 0–10 V; RS485; combined outputs |
| LFM52 | ±100 / ±1000 / ±10000 | ±1% FS | −20 to +70 | IP65 | 4–20 mA; 0–5 V; 0–10 V; RS485; combined current/voltage |
| LFM55 | ±25 / ±50 / ±100 | ±1 Pa | −20 to +70 | IP30 | 4–20 mA + 0–10 V; or RS485 |
| LFM751 | ±100 / ±1000 / ±10000 | ±0.5% FS for range ≥500 Pa; ±1% FS below500 Pa | −20 to +70 | IP65 | 4–20 mA, two-wire |
| LFM76 | ±100 / ±1000 / ±10000 | ±1% FS | −20 to +80 | IP65 | 4–20 mA + RS485; 4–20 mA + 0–10 V; 0–10 V + RS485 |
| LFM77 | ±100 / ±1000 / ±10000 | ±1% FS | −20 to +80 | IP65 | 4–20 mA; or 0–10 V; or RS485 |
Range Codes
| Series | Range code | Range |
|---|---|---|
| LFM108 | 101G | 0–100 Pa |
| LFM108 | 102G | 0–1000 Pa |
| LFM108 | 103G | 0–10000 Pa |
| LFM108 | 251G | 0–250 Pa |
| LFM108 | 252G | 0–2500 Pa |
| LFM108 | 501G | 0–500 Pa |
| LFM108 | 502G | 0–5000 Pa |
| LFM108 | 051D | ±50 Pa |
| LFM108 | 101D | ±100 Pa |
| LFM108 | 102D | ±1000 Pa |
| LFM108 | 103D | ±10000 Pa |
| LFM108 | 251D | ±250 Pa |
| LFM108 | 252D | ±2500 Pa |
| LFM108 | 501D | ±500 Pa |
| LFM108 | 502D | ±5000 Pa |
| LFM11 | 6 | ±100 Pa |
| LFM11 | 0 | ±1000 Pa |
| LFM11 | 2 | ±10000 Pa |
| LFM52 | 6 | ±100 Pa |
| LFM52 | 0 | ±1000 Pa |
| LFM52 | 2 | ±10000 Pa |
| LFM751 | 6 | ±100 Pa |
| LFM751 | 0 | ±1000 Pa |
| LFM751 | 2 | ±10000 Pa |
| LFM76 | 1 | ±100 Pa |
| LFM76 | 2 | ±1000 Pa |
| LFM76 | 3 | ±10000 Pa |
| LFM76 | X | Custom; confirm range |
| LFM77 | 1 | ±100 Pa |
| LFM77 | 2 | ±1000 Pa |
| LFM77 | 3 | ±10000 Pa |
| LFM77 | X | Custom; confirm range |
| LFM55 | 1 | ±25 Pa |
| LFM55 | 2 | ±50 Pa |
| LFM55 | 3 | ±100 Pa |
| LFM55 | 4 | Custom; confirm range |
Output Codes
| Series | Output code | Signal |
|---|---|---|
| LFM108 | AL | 4–20 mA |
| LFM108 | VL | 0–10 VDC |
| LFM108 | VZ | 0–5 VDC |
| LFM108 | MOD | RS485 |
| LFM108 | MVL | RS485 + 0–10 VDC |
| LFM108 | MVZ | RS485 + 0–5 VDC |
| LFM11 | A | 4–20 mA + 0–10 V simultaneously |
| LFM11 | B | 4–20 mA, two-wire, no backlight |
| LFM11 | C | 0–10 V, three-wire |
| LFM11 | D | 0–5 V, three-wire |
| LFM52 | A | 4–20 mA + 0–10 V simultaneously |
| LFM52 | B | 4–20 mA, two-wire, no backlight |
| LFM52 | C | 0–10 V, three-wire |
| LFM52 | D | 0–5 V, three-wire |
| LFM11 | Confirm code | RS485 |
| LFM11 | F | 0–10 V + RS485 |
| LFM52 | E | RS485 |
| LFM52 | E1 | Isolated RS485 |
| LFM55 | A | 4–20 mA + 0–10 V simultaneously |
| LFM55 | E | RS485 |
| LFM751 | Fixed | 4–20 mA, two-wire |
| LFM76 | A | 4–20 mA + RS485 |
| LFM76 | B | 4–20 mA + 0–10 V |
| LFM76 | C | 0–10 V + RS485 |
| LFM77 | A | 4–20 mA |
| LFM77 | B | 0–10 V |
| LFM77 | C | RS485 |
Power Supply by Configuration
| Series | Configuration | Supply |
|---|---|---|
| LFM108 | 4–20 mA / voltage / RS485 / voltage+RS485 | 10–30 / 16–30 / 12–30 / 16–30 VDC |
| LFM11 | 4–20 mA / voltage / RS485 / combined | 12–30 / 16–30 / 12–30 / 16–30 VDC |
| LFM52 | 4–20 mA | 12–30 VDC |
| LFM52 | Voltage or current+voltage | 12–30 VDC or 24 VAC ±20% |
| LFM52 | RS485 | 9–30 VDC |
| LFM55 | RS485 | 9–30 VDC or 24 VAC ±20% |
| LFM55 | Current+voltage | 12–30 VDC or 24 VAC ±20% |
| LFM751 | 4–20 mA | 12–30 VDC |
| LFM76 / LFM77 | Listed output configurations | 12–30 VDC or 24 VAC ±20% |
Envelope Dimensions
| Series | Width (mm) | Height (mm) | Depth (mm) | Drawing notes |
|---|---|---|---|---|
| LFM108 | 97 overall; 90 body | 87 | 35.5 | M16 cable gland; Ø6.2 pressure ports |
| LFM11 | 90 | 105 overall; 80 body | 44.5 | M16 cable gland; Ø6.2 pressure ports |
| LFM52 | 100 | 103 overall; 80 body | 46 | M16 cable gland; Ø6.2 pressure ports |
| LFM55 | 110 | 100 | 33.5 overall; 31.5 behind panel | Front panel dimensions; see drawing |
| LFM751 | 112 overall; 100 inner span | 91 overall; 78 body | 39 | Grounding screw labelled in original drawing |
| LFM76 | 179±2 | 159±2 | 108±1 | Mounting spans124±1 and136±1; M20×1.5 |
| LFM77 | 179±2 | 168±2 | 92.5±1 | Mounting spans124±1 and144.7±1; M20×1.5 |
Select the series, range, output and power supply together. Options and dimensions differ by model; the photographs do not imply identical configurations. LFM55 offers local audible and visual alarms. Confirm hazardous-area certification and installation requirements for the exact LFM751, LFM76 or LFM77 configuration before specifying hazardous-area service. For AC-powered LFM55/76/77 installations, the supplier recommends an isolated AC supply. LFM108 stability and overload limits and LFM751 overload limits require version-specific confirmation.
LFM751 drawing label: grounding screw. All drawing dimensions are in millimetres.