DODOMACH PNEUMATIC

Pressure Transmitters

Refrigeration Pressure Transmitter

Compact refrigeration pressure transmitter with ceramic capacitive sensing and a three-wire ratiometric voltage output. Designed for refrigerant pressure measurement in air-conditioning and refrigeration systems, with a Packard electrical connector and male or female threaded process connections.

Dimensions and Structure

Refrigeration Pressure Transmitter dimensions

Refrigeration Pressure Transmitter

Compact refrigeration pressure transmitter with ceramic capacitive sensing and a three-wire ratiometric voltage output. Designed for refrigerant pressure measurement in air-conditioning and refrigeration systems, with a Packard electrical connector and male or female threaded process connections.

Operating Specifications

Item Value
Sensing principle Ceramic capacitive
Pressure reference Gauge (G)
Range selection Zero-based spans with full scale from 10 to 50 bar
Output 0.5–4.5 V ratiometric; three-wire
Supply 4.75–5.25 VDC
Overload 2 times rated pressure
Burst pressure 3 times rated pressure
Electrical connection Packard plug
Protection IP67
Insulation test 500 VAC for 60 seconds

Temperature and Accuracy Selection

Temperature code Working temperature Catalog accuracy grade
T1 −20 to +80 °C 1.5: ±1.5% FS
T2 −40 to +120 °C 2.5: ±2.5% FS

Ordering Fields

Field Code / selection
Range Select required zero-based span within the catalog range
Pressure unit K: kPa; P: psi; M: MPa; B: bar
Output V05: 0.5–4.5 V ratiometric, three-wire
Connector P: Packard
Process connection A: 7/16-20 UNF male; B: 7/16-20 UNF female
Cable length 1.0: 1 m; 2.0: 2 m

Illustrated Connection Dimensions

Version Height (mm) Body diameter (mm) Wrench size (mm) Thread
Female 54±3 25±0.2 27 7/16-20 UNF-2B
Male 57±3 25±0.2 27 7/16-20 UNF-2A

Catalog reference: LFT2060. Specifications and photographs on this page apply to this catalog series. The catalog lists R12, R22, R32, R134a, R404a, R407c, R410a, R502 and R507; confirm the selected seals and operating conditions for the intended refrigerant. Select range, unit, output, accuracy/temperature grade, connector, pressure connection and cable length. Confirm the complete ordering string with the supplier. The original dimension drawing shows the female-thread version; the male version has a different height. Dimensions are in millimetres. No international-brand interchangeability or certification is claimed.