Electromagnetic flowmeter for forward and reverse flow measurement of conductive liquids. Integral and remote converter options support water, wastewater and industrial liquid monitoring.
The illustrated LFLD configuration has an integral converter and flanged connections. Select the converter and power version together; output availability depends on the selected configuration.
Measurement and Operating Specifications
| Item | Specification |
|---|---|
| Principle | Electromagnetic; conductive liquids |
| Nominal diameter range | DN10–DN3000 |
| Maximum velocity | 15 m/s |
| Fluid conductivity | >50 µS/cm |
| Stated accuracy | 0.5% |
| Measurement direction | Forward and reverse |
| Output options | 4–20 mA; HART and RS485 according to converter |
| Power options | 20–36 VDC; 85–250 VAC; battery-powered version |
| Power consumption | <20 W |
| Ambient temperature | −10 to +60 °C |
| Standard electrodes | Three: two measurement electrodes and one grounding electrode |
| Remote signal cable | 10 m standard; longer cable custom, below100 m |
Nominal Pressure Selection
| Diameter | Pressure |
|---|---|
| DN10–DN200 | 1.6 MPa |
| DN250–DN1000 | 1.0 MPa |
| DN1200–DN2000 | 0.6 MPa |
| DN2200–DN3000 | 0.6 MPa |
| Special configuration | 2.5 or4.0 MPa by custom confirmation |
Configuration Selection
| Field | Code | Option |
|---|---|---|
| Construction | 1 | Remote converter |
| Construction | 2 | Integral converter |
| Supply | 1 | 85–250 VAC |
| Supply | 2 | 20–36 VDC |
| Supply | 3 | Battery version |
| Converter | MB | Push buttons, two-row display, standard output and RS485 |
| Converter | LB | Push buttons, two-row display, standard output, RS485 and HART |
| Protection | 1 | IP65 |
| Protection | 2 | IP68 sensor with IP65 converter |
Wetted Material Selection
| Field | Code | Option |
|---|---|---|
| Liner | 1 | PTFE |
| Liner | 2 | Neoprene |
| Liner | 3 | Polyurethane |
| Liner | 4 | FEP |
| Electrode | 1 | 316L stainless steel |
| Electrode | 2 | Hastelloy B |
| Electrode | 3 | Hastelloy C |
| Electrode | 4 | Titanium |
| Electrode | 6 | Tantalum |
| Electrode | 7 | Tungsten-carbide-coated stainless steel |
Drawing Symbols
| Symbol | Meaning |
|---|---|
| L | Face-to-face length |
| H1 | Height shown |
| D | Flange outside diameter |
| d1 | Bolt circle diameter |
| n-d0 | Number and diameter of mounting holes |
Dimensional Reference Drawing
Ordering Information
Specify the LFLD family, nominal diameter, pressure, liner, electrode material, integral or remote construction, power supply, converter and protection option. Confirm the complete ordering designation and compatibility for the actual liquid.
Select diameter, pressure rating, liner, electrodes, power and converter together for the actual liquid and installation. The illustrated product has an integral converter and flanged connections. The 0.5% accuracy is the supplier-stated specification; detailed error basis and calibration conditions require confirmation. IP68 refers to the selected sensor, with an IP65 converter. The drawing identifies dimension symbols; obtain the numerical drawing for the chosen size and pressure before installation. Battery versions require confirmation of supported outputs and operating life.