Electronic level-sensing condensate drains discharge collected liquid from compressed-air filters, dryers and receivers when the liquid reaches the switching level. Level-based opening and closing limits unnecessary compressed-air discharge.
Choose a compact filter-mounted drain, an external chamber drain, or a capacitive diaphragm drain. These configurations have different connections, capacities and electrical requirements. The main photograph shows the capacitive diaphragm configuration; the compact installation drawing applies only to the compact filter-mounted version.
Compact filter-mounted drain
| Parameter | Catalog specification |
|---|---|
| Control | Electronic liquid-level sensing with TEST function |
| Pressure | 0–1.6 MPa |
| Drainage capacity | 45 L/h |
| Operating temperature | 1.5–65 °C |
| Inlet | G1/2 |
| Drain outlet | 8 mm |
| Power selection | Specify and confirm the actual supply-voltage version before ordering |
| Drawing dimensions | 111 mm drain height below connection; 61 mm front width; 60 mm side width |
External chamber drain selection
| Compressor class (m³/min) | Maximum dryer capacity (m³/min) | Maximum filter capacity (m³/min) | Pressure (MPa) | Inlet | Outlet |
|---|---|---|---|---|---|
| 40 | 80 | 400 | 0–1.6 | G1/2 | G3/8 |
| 60 | 120 | 600 | 0–1.6 | G1/2 | G3/8 |
| 180 | 360 | 1800 | 0–1.6 | G3/4 | G3/8 |
| 300 | 600 | 3000 | 0–1.6 | G1 | G3/8 |
External chamber dimensions and electrical options
| Compressor class (m³/min) | Catalog dimensions (mm) | Valve orifice | Catalog voltage options |
|---|---|---|---|
| 40 | 70 × 65 × 203 | 10 mm | 100 VAC or 200 VAC |
| 60 | 180 × 75 × 203 | 10 mm | 100 VAC or 200 VAC |
| 180 | 180 × 95 × 216 | 10 mm | 100 VAC or 200 VAC |
| 300 | 200 × 110 × 213 | 10 mm | 100 VAC or 200 VAC |
Capacitive diaphragm drain selection
| Compressor class (m³/min) | Maximum dryer capacity (m³/min) | Maximum filter capacity (m³/min) | Pressure (MPa) | Inlet | Outlet |
|---|---|---|---|---|---|
| 180 | 360 | 1800 | 0–1.0 | G1/2 | G1/2 |
| 300 | 600 | 3000 | 0–1.0 | G3/4 | G1/2 |
Capacitive diaphragm drain controls
| Feature | Specification |
|---|---|
| Level detection | Capacitive sensor |
| Discharge operation | Pilot valve opens the diaphragm drain when condensate reaches the switching level |
| Valve orifice | 10 mm |
| Catalog power options | 100 VAC or 200 VAC; confirm the actual unit rating before wiring |
| Local indication | Power, valve and alarm indicators; TEST button |
| Alarm | Alarm signal connection described; electrical ratings must be confirmed for the selected version |
Level-controlled discharge cycle
| Step | Action |
|---|---|
| 1 | Condensate collects in the chamber |
| 2 | At high level, the sensor commands the drain valve to open |
| 3 | At low level, the sensor commands the valve to close |
| 4 | Residual liquid remains above the outlet to limit compressed-air discharge |
Selection and installation notes
Compressor, dryer and filter figures are catalog selection capacities, not liquid-drainage rates. They require confirmation against actual system conditions. The compact version is rated separately at 45 L/h. Temperature limits listed for the compact unit must not be applied to the larger chamber or capacitive versions.
The capacitive diaphragm source lists 100 VAC/200 VAC in its specifications but describes 24 VDC in a separate wiring paragraph. Confirm the supplied nameplate and wiring diagram before connection; do not assume a universal-voltage unit. Alarm contact ratings and connections also require confirmation for the selected version.
The compact version is identified as electronic liquid-level sensing. Capacitive sensing is explicitly specified for the capacitive diaphragm versions. Catalog dimensions are retained in their original sequence; confirm the installation drawing for the selected configuration.
Compact filter-mounted installation

Level-controlled operating cycle

Capacitive diaphragm operating section