DODOMACH PNEUMATIC

Air Source Treatment (F.R.L.)

Electronic Level-Sensing Condensate Drains

Electronic liquid-level control for compressed-air condensate discharge. Compact filter-mounted, external chamber and capacitive diaphragm configurations are available, with separate capacity, connection and supply-voltage selections.

Electronic level-sensing condensate drains discharge collected liquid from compressed-air filters, dryers and receivers when the liquid reaches the switching level. Level-based opening and closing limits unnecessary compressed-air discharge.

Choose a compact filter-mounted drain, an external chamber drain, or a capacitive diaphragm drain. These configurations have different connections, capacities and electrical requirements. The main photograph shows the capacitive diaphragm configuration; the compact installation drawing applies only to the compact filter-mounted version.

Compact filter-mounted drain

Parameter Catalog specification
Control Electronic liquid-level sensing with TEST function
Pressure 0–1.6 MPa
Drainage capacity 45 L/h
Operating temperature 1.5–65 °C
Inlet G1/2
Drain outlet 8 mm
Power selection Specify and confirm the actual supply-voltage version before ordering
Drawing dimensions 111 mm drain height below connection; 61 mm front width; 60 mm side width

External chamber drain selection

Compressor class (m³/min) Maximum dryer capacity (m³/min) Maximum filter capacity (m³/min) Pressure (MPa) Inlet Outlet
40 80 400 0–1.6 G1/2 G3/8
60 120 600 0–1.6 G1/2 G3/8
180 360 1800 0–1.6 G3/4 G3/8
300 600 3000 0–1.6 G1 G3/8

External chamber dimensions and electrical options

Compressor class (m³/min) Catalog dimensions (mm) Valve orifice Catalog voltage options
40 70 × 65 × 203 10 mm 100 VAC or 200 VAC
60 180 × 75 × 203 10 mm 100 VAC or 200 VAC
180 180 × 95 × 216 10 mm 100 VAC or 200 VAC
300 200 × 110 × 213 10 mm 100 VAC or 200 VAC

Capacitive diaphragm drain selection

Compressor class (m³/min) Maximum dryer capacity (m³/min) Maximum filter capacity (m³/min) Pressure (MPa) Inlet Outlet
180 360 1800 0–1.0 G1/2 G1/2
300 600 3000 0–1.0 G3/4 G1/2

Capacitive diaphragm drain controls

Feature Specification
Level detection Capacitive sensor
Discharge operation Pilot valve opens the diaphragm drain when condensate reaches the switching level
Valve orifice 10 mm
Catalog power options 100 VAC or 200 VAC; confirm the actual unit rating before wiring
Local indication Power, valve and alarm indicators; TEST button
Alarm Alarm signal connection described; electrical ratings must be confirmed for the selected version

Level-controlled discharge cycle

Step Action
1 Condensate collects in the chamber
2 At high level, the sensor commands the drain valve to open
3 At low level, the sensor commands the valve to close
4 Residual liquid remains above the outlet to limit compressed-air discharge

Selection and installation notes

Compressor, dryer and filter figures are catalog selection capacities, not liquid-drainage rates. They require confirmation against actual system conditions. The compact version is rated separately at 45 L/h. Temperature limits listed for the compact unit must not be applied to the larger chamber or capacitive versions.

The capacitive diaphragm source lists 100 VAC/200 VAC in its specifications but describes 24 VDC in a separate wiring paragraph. Confirm the supplied nameplate and wiring diagram before connection; do not assume a universal-voltage unit. Alarm contact ratings and connections also require confirmation for the selected version.

The compact version is identified as electronic liquid-level sensing. Capacitive sensing is explicitly specified for the capacitive diaphragm versions. Catalog dimensions are retained in their original sequence; confirm the installation drawing for the selected configuration.

Compact filter-mounted installation

Electronic level-sensing condensate drain compact installation dimensions

Level-controlled operating cycle

Electronic level-sensing condensate drain operating cycle

Capacitive diaphragm operating section

Electronic level-sensing condensate drain diaphragm section