DODOMACH PNEUMATIC

Vacuum Units

Integrated-control Vacuum Generators

Compressed-air vacuum generation with integrated supply and release control, in single-unit and manifold configurations. The main image shows an MC22 manifold assembly (Version C).

Category

Integrated vacuum generation and control

The main image shows an MC22 manifold assembly (Version C). Sensor and station configurations vary by selection.

Compressed-air vacuum generators combine vacuum generation with supply and release control. Single-unit and manifold arrangements are available. Sensor, check-valve and self-holding valve options depend on the selected version.

A1–A8, B1–B3 and C1–C8 are page-local selection references, not manufacturer ordering codes. Parameters and dimensions are specific to each version and must not be combined across versions.

Version A — 10 mm controlled ejector

Version A — 10 mm body

Configuration Rated supply (MPa) Attainable vacuum (kPa) Suction flow (L/min ANR) Release flow (L/min ANR) Release test pressure (MPa) Air consumption (L/min ANR)
A1 0.5 -90 8.5 40 0.5 10
A2 0.18 -83 10 20 0.2 10
A3 0.5 -87 5.5 40 0.5 10
A4 0.5 -87 11 40 0.5 22.5
A5 0.5 -87 20 40 0.5 50
A6 0.35 -87 4 30 0.35 10
A7 0.35 -87 9 30 0.35 22.5
A8 0.35 -87 15 30 0.35 55

Version A — operating specifications

Property Specification
Working fluid Oil-free compressed air
Operating pressure 0.1–0.55 MPa
Ambient temperature 0–55 °C; no freezing
Body width 10 mm
Manifold capacity 1–6 stations
Supply-valve options Normally closed or self-holding
Solenoid supply 24 V DC ±10%
Normally closed solenoid power 1 W
Single-unit mass 125 g with specified sensor

Version B — compact controlled ejector

Version B manifold dimensions; sensor selection changes the envelope.
Version B manifold dimensions; sensor selection changes the envelope.

Version B — compact unit

Configuration Rated supply (MPa) Attainable vacuum (kPa) Suction flow (L/min ANR) Release flow (L/min ANR) Release test pressure (MPa) Air consumption (L/min ANR)
B1 0.5 -85 2.5 9 0.5 8.5
B2 0.5 -86.6 5 9 0.5 12
B3 0.4 -86.6 4 8 0.4 12

Manifold station selection

Stations n A (mm) B (mm) C (mm)
1 38.5 30.5 24.5
2 49 40 34
3 59.5 51.5 45.5
4 70 62 56
5 80.5 72.5 66.5
6 91 83 77
7 101.5 93.5 87.5
8 112 104 98

Manifold dimensions

Dimension or connection Value
Without sensor: length 81.2 mm
Without sensor: height 48 mm
With V9/10 sensor: length 99.7 mm
With V9/10 sensor: height 77.5 mm
With V8 sensor: length 93.7 mm
With V8 sensor: height 45.5 mm
Compressed-air supply 2 × Rc1/8
Vacuum ports One M5 port per station
Mounting holes 2 × Ø3.3 mm
Station pitch 10.5 mm

Operating and electrical specifications

Item Value
Medium Oil-free compressed air
Operating pressure 0.2–0.6 MPa
Ambient temperature 0–55 °C; no freezing
Supply-valve options Normally closed or self-holding; B3: normally closed only
Solenoid supply 24 V DC ±10%
Normally closed solenoid power 1 W
Solenoid insulation Class B
Manual override Non-locking
Indicator / surge suppression LED / diode
Solenoid lead length 300 mm

Configuration B3 uses normally closed supply-valve operation only. Manifold dimensions depend on the selected sensor configuration.

Version C — 20 mm controlled ejector

Version C sectional view. Numbered components are identified below; this drawing does not represent Versions A or B.
Version C sectional view. Numbered components are identified below; this drawing does not represent Versions A or B.

Version C — 20 mm body

Configuration Nozzle diameter (mm) Rated supply (MPa) Attainable vacuum (kPa) Suction flow (L/min ANR) Air consumption (L/min ANR)
C1 0.5 0.5 -87 6 10
C2 0.5 0.5 -53 11 10
C3 0.5 0.35 -87 4 10
C4 0.7 0.5 -87 11 22.5
C5 0.7 0.5 -53 21 22.5
C6 0.7 0.35 -87 9 22.5
C7 1 0.5 -87 20 48
C8 1 0.35 -87 15 48

Version C — operating specifications

Property Specification
Working fluid Oil-free compressed air
Operating pressure 0.2–0.5 MPa
Ambient temperature 0–50 °C; no freezing
Body width 20 mm
Manifold capacity Up to 8 stations; configuration-dependent
Supply-valve options Normally open, normally closed or self-holding
Solenoid supply 24 V DC
Filter average pore size 37 µm
Single-unit mass, without check valve 113 g
Single-unit mass, with check valve 129 g

Version C — manifold station dimensions, with or without check valve

Stations A (mm) B (mm)
1 36 28
2 56.5 48.5
3 77 69
4 97.5 89.5
5 118 110
6 138.5 130.5
7 159 151
8 179.5 171.5

Version C — configuration-specific dimensions

Configuration Dimension Value (mm)
Single, no check valve Overall length, Rc version 86.6
Single, no check valve Overall length, NPT version 88.9
Single, with check valve Overall length, Rc version 97.6
Single, with check valve Overall length, NPT version 99.9
Manifold, no check valve Overall length shown 86.6
Manifold, with check valve Overall length shown 97.6
Manifold, both check-valve options Station pitch 20.5
Manifold, both check-valve options Mounting-hole diameter (4 holes) 4.5
Single, both check-valve options Body width 20

Version C — sectional drawing key

No. Component
1 Air-supply base
2 Poppet valve
3 Pilot solenoid valve
4 Cover
5 Valve body section
6 Gasket section
7 Nozzle element
8 Silencer
9 Filter assembly
10 Vacuum-port base
11 Vacuum sensor

Optional pressure-based control stops and restarts generation according to the vacuum setting. Suitability depends on leakage and workpiece porosity. Self-holding valve selection does not establish safety-rated load retention. Select ports, valve operation, sensing and station count for the required configuration.