Dimensions and Structure

Refrigeration Capacity Bypass Valve
Refrigeration bypass valve for capacity regulation in systems with non-adjustable compressors. The valve modulates in response to outlet pressure to maintain the selected pressure, and can serve as a constant-pressure automatic expansion valve.
Connections and Dimensions
| Selection size | Inlet A | Outlet B | C (mm) | D (mm) | E (mm) | F (mm) |
|---|---|---|---|---|---|---|
| 0.5 / 1.0 / 2.0 / 3.0 / 4.0 | 6 mm ODF | 10 mm ODF | 58 | 36 | 106 | 54 |
| 0.5 / 1.0 / 2.0 / 3.0 / 4.0 | 1/4 in ODF | 3/8 in ODF | 58 | 36 | 106 | 54 |
| 5.0 / 6.0 | 10 mm ODF | 16 mm ODF | 64 | 47 | 122 | 69 |
| 5.0 / 6.0 | 3/8 in ODF | 5/8 in ODF | 64 | 47 | 122 | 69 |
Nominal Refrigerating Capacity (kW)
| Selection size | R134a | R22 | R404A | R507 |
|---|---|---|---|---|
| 0.5 | 0.98 | 1.4 | 1.0 | 1.0 |
| 1.0 | 1.4 | 2.1 | 1.5 | 1.5 |
| 2.0 | 2.9 | 4.2 | 3.0 | 3.0 |
| 3.0 | 6.7 | 9.8 | 6.8 | 6.9 |
| 4.0 | 8.9 | 12.8 | 9.0 | 9.0 |
| 5.0 | 16.3 | 23.6 | 16.5 | 16.6 |
| 6.0 | 20.4 | 30.6 | 21.4 | 21.6 |
Operating Information
| Item | Value |
|---|---|
| Catalog family | LFDBV |
| Maximum working pressure | 28 bar |
| Controlled variable | Outlet pressure |
| Connection | ODF solder |
| Application | Capacity regulation for refrigeration systems with non-adjustable compressors |
Selection-size identifiers are catalog codes, not connection diameters or capacity units. Choose the metric or inch connection option explicitly. Capacities are nominal supplier values; confirm the refrigerant, required outlet-pressure setting, temperature limits and design operating conditions before ordering. Maximum working pressure is not the adjustment range.