Vacuum Pressure Controllers with Suction and Release Valve Control
Pressure-feedback controllers with a suction/release command input and dedicated control of vacuum-generation and release solenoid valves. Select the sensor output, command-input type, valve-drive connection and operating mode together. The main image shows the MVS-201 version.
These controllers require the matching external solenoid valves and vacuum equipment. Switching output current is not a solenoid-drive rating. The two consumption values use different scopes and must not be directly compared.
Original connection diagrams and dimensions




Controller specifications
| Parameter | MPS-10 | MVS-201 |
|---|---|---|
| Pressure setting range (kPa) | -101 to 500 | -101 to 500 |
| Proof pressure (MPa) | 0.8 | 0.8 |
| Nominal supply (V DC) | 24 | 24 |
| Supply ripple | 5% peak-to-peak maximum | 5% peak-to-peak maximum |
| Consumption (mA) | 50 maximum, excluding solenoid drive | 45, including solenoid drive (source scope) |
| Switching output | One NPN or PNP open collector | One NPN or PNP open collector |
| Switching load (mA) | 125 maximum | 125 maximum |
| Analog output | 1 to 5 V; output resistance 1 kOhm | Not specified |
| Command input | One contactless input; 0 V or 24 V; at least 1 ms | One contactless input; at least 1 ms |
| Response time (ms) | 1.5 maximum | 2.5 |
| Operating temperature (C) | 0 to 50 | 0 to 50 |
| Protection | IP40 | IP40 |
| Display | 3-digit red seven-segment | 3-digit red seven-segment |
| Display resolution (kPa) | 1 | 1 |
| Display update (s) | 0.2 | 0.2 |
| Electrical connection | 5-core connector; supplier-specific valve cable | M8 four-pin; 2 m cable option |
| Mass | 10 g without cable | Confirm with selected assembly |
| Body dimensions | 50 x 20 x 9.9 mm; see drawing | See corresponding original drawing |
Output and installation selection
| Version | Available selection | Restriction |
|---|---|---|
| MPS-10 standalone | NPN output with sink command input | NPN with source command input is unavailable |
| MPS-10 standalone | PNP output with sink or source command input | Match the selected wiring diagram |
| MPS-10 mounted | NPN or PNP; supplier-specific generator and cable | A/B/W valve states selected with the matching assembly |
| MVS-201 standalone | NPN or PNP output; M8 four-pin connection | Cable and mating valve connection selected separately |
| MVS-201 mounted | NPN or PNP; supplier-specific generator adapter | Self-holding valve option excludes OP1 |
MVS-201 operating modes
| Mode | Generation control | Release |
|---|---|---|
| OP1: pressure-feedback saving | Stops at the set vacuum and restarts when vacuum falls | Release follows removal of suction command |
| OP2: timed-off | Stops after the set pressure condition; does not restart solely because vacuum falls | Release follows removal of suction command |
| OP3: continuous | Generation remains on while suction command is present | Release follows removal of suction command |
OP1 is unavailable with the self-holding valve option. Do not apply these MVS-201 mode details automatically to another controller. The MVS-201 specification table gives nominal 24 V DC; its circuit drawing separately prints a wider voltage range. Use the nominal table rating until the selected assembly is confirmed. The catalogue mass entry for MVS-201 includes a cable but conflicts with the assembly context, so no mass is assigned here. Wiring, drive capacity and cable compatibility must match the specific selected controller and valves; no cross-brand interchangeability is claimed.