Version A

Version A has an adjustable nozzle and threaded ends. Performance values below use 5.5 bar supply. Air consumption and vacuum flow are distinct quantities.
Version A — performance
| Configuration | Bore (mm) | Supply (bar) | Vacuum magnitude (-kPa) | Air consumption (NL/min) | Vacuum flow (NL/min) |
|---|---|---|---|---|---|
| A1 | 6.5 | 5.5 | 17 | 112 | 280 |
| A1 | 6.5 | 5.5 | 34 | 169 | 240 |
| A1 | 6.5 | 5.5 | 50 | 233 | 200 |
| A1 | 6.5 | 5.5 | 68 | 276 | 162 |
| A1 | 6.5 | 5.5 | 84 | 342 | 125 |
| A2 | 9.5 | 5.5 | 17 | 176 | 846 |
| A2 | 9.5 | 5.5 | 34 | 327 | 735 |
| A2 | 9.5 | 5.5 | 50 | 485 | 620 |
| A2 | 9.5 | 5.5 | 68 | 595 | 520 |
| A2 | 9.5 | 5.5 | 84 | 825 | 395 |
| A3 | 13 | 5.5 | 17 | 340 | 1695 |
| A3 | 13 | 5.5 | 34 | 625 | 1325 |
| A3 | 13 | 5.5 | 50 | 795 | 1130 |
| A3 | 13 | 5.5 | 68 | 940 | 990 |
| A3 | 13 | 5.5 | 84 | 1280 | 650 |
| A4 | 19 | 5.5 | 17 | 650 | 3390 |
| A4 | 19 | 5.5 | 34 | 875 | 2460 |
| A4 | 19 | 5.5 | 50 | 1250 | 1970 |
| A4 | 19 | 5.5 | 68 | 1790 | 1440 |
| A4 | 19 | 5.5 | 84 | 2550 | 1130 |
Version A — dimensions (mm; threads as marked)
| Configuration | A | B | C | D | E | F | H | G1 vacuum | G2 supply | G3 exhaust |
|---|---|---|---|---|---|---|---|---|---|---|
| A1 | 6.5 | 19 | 32 | 94–105 | 22 | 32 | 5 | G1/4 | G1/8 | G1/4 |
| A2 | 9.5 | 25 | 45 | 155–165 | 38 | 45 | 5 | G3/8 | G3/8 | G1/2 |
| A3 | 13 | 32 | 51 | 155–160 | 38 | 51 | 5 | G1/2 | G3/8 | G3/4 |
| A4 | 19 | 38 | 58 | 175–189 | 38 | 51 | 5 | G3/4 | G1/2 | G1 |
Version B; B2 left, other configurations right

Version B rated supply is 6 bar. Air consumption is separately specified at 2.8 and 5.5 bar. B2 uses the left threaded-end drawing; other configurations use the right drawing.
Version B — performance
| Configuration | Bore (mm) | Maximum vacuum magnitude (-kPa) | Maximum vacuum flow (NL/min) | Air consumption at 2.8 bar (NL/min) | Air consumption at 5.5 bar (NL/min) |
|---|---|---|---|---|---|
| B1 | 6.5 | 26 | 295 | 85 | 160 |
| B2 | 9.5 | 16 | 425 | 95 | 170 |
| B3 | 12.5 | 35 | 870 | 395 | 680 |
| B4 | 19 | 28 | 1825 | 790 | 1365 |
| B5 | 25 | 4.4 | 4400 | 405 | 695 |
| B6 | 38 | 9 | 5610 | 790 | 1365 |
Version B — dimensions (mm; threads as marked)
| Configuration | A | B | C | D | E | F | G | H | I | J mounting | K supply |
|---|---|---|---|---|---|---|---|---|---|---|---|
| B1 | 6.5 | 18.5 | 32 | 28 | 89 | 19 | 25 | 18 | 19.5 | M4×0.7 | G1/8 |
| B2 | 9.5 | 18.5 | 32 | 28 | 89 | 19 | 25 | 18 | 19.5 | M4×0.7 | G1/8 |
| B3 | 12.5 | 24 | 38 | 34 | 140 | 25 | 32 | 23 | 25 | M4×0.7 | G1/4 |
| B4 | 19 | 31 | 50 | 45 | 190 | 38 | 50 | 35 | 33 | M4×0.7 | G3/8 |
| B5 | 25 | 38 | 59 | 55 | 198 | 40 | 56 | 40 | 38 | M4×0.7 | G3/8 |
| B6 | 38 | 49.6 | 69 | 65 | 205 | 40 | 60 | 42 | 49.6 | M4×0.7 | G3/8 |
Version C

Version C uses 5 bar rated supply. Compressed air enters laterally to create flow through the straight bore.
Version C — performance
| Configuration | Bore (mm) | Maximum vacuum magnitude (-kPa) | Maximum vacuum flow (NL/min) | Air consumption (NL/min) | Mass (g) |
|---|---|---|---|---|---|
| C1 | 10 | 12 | 550 | 140 | 77 |
| C2 | 20 | 4 | 1375 | 265 | 189 |
| C3 | 40 | 2 | 2250 | 470 | 522 |
| C4 | 75 | 1 | 8640 | 876 | 2308 |
Version C — dimensions (mm; threads as marked)
| Configuration | A | B | C | D | E | F | G supply | H | K | M mounting |
|---|---|---|---|---|---|---|---|---|---|---|
| C1 | 70 | 23 | 21 | 37 | 19 | 19 | G1/8 | 10 | 29 | 2-M4×0.7 |
| C2 | 86 | 30 | 30 | 50 | 32 | 38 | G1/4 | 20 | 41.5 | 2-M4×0.7 |
| C3 | 94 | 30 | 34 | 84 | 52 | 75 | G3/8 | 40 | 72 | 2-M4×0.7 |
| C4 | 180 | 34 | 65 | 140 | 100 | 125 | G1/2 | 75 | 126 | 2-M6×1 |
Operating temperature: -20 to 80 °C. Flow units are NL/min. Maximum vacuum and maximum vacuum flow are separate performance limits and do not describe a simultaneous operating point.